Your browser doesn't support javascript.
loading
High-Performance Photovoltaic Hydrogen Sensing Platform with a Light-Intensity Calibration Module.
Kim, Hyeonghun; Kim, Woochul; Lee, Ryeri; Cho, Sungjun; Park, Jiyoon; Pak, Yusin; Jung, Gun Young.
Affiliation
  • Kim H; School of Materials Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea.
  • Kim W; School of Materials Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea.
  • Lee R; School of Materials Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea.
  • Cho S; School of Materials Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea.
  • Park J; School of Materials Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea.
  • Pak Y; Sensor System Research Center (SSRC), Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea.
  • Jung GY; School of Materials Science and Engineering, Gwangju Institute of Science and Technology (GIST), Gwangju 61005, Republic of Korea.
ACS Sens ; 5(4): 1050-1057, 2020 04 24.
Article in En | MEDLINE | ID: mdl-32223147
ABSTRACT
Although battery-free gas sensors (e.g., photovoltaic or triboelectric sensors) have recently appeared to resolve the power consumption issue of conventional chemiresistors, severe technical barriers still remain. Especially, their signals varying under ambient conditions such as light intensity restrict the utilization of these sensors. Insufficient sensing performances (low response and slow sensing rate) of previous battery-free sensors are also an obstacle for practical use. Herein, a photovoltaic hydrogen (H2)-sensing platform having constant sensing responses regardless of light conditions is demonstrated. The platform consists of two photovoltaic units (1) a palladium (Pd)-decorated n-IGZO/p-Si photodiode covered with a microporous zeolitic imidazolate framework-8 (ZIF-8) film and (2) a device with the same configuration, but without the Pd catalyst as a reference to calibrate the base current of sensor (1). The platform after calibration yields accurate response values in real time regardless of unknown irradiance. Besides, the sensing performances (e.g., sensing response of 1.57 × 104% at 1% H2 with a response time <15 s) of our platform are comparable with those of the conventional resistive H2 sensors, which yield unprecedented results in photovoltaic H2 sensors.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Hydrogen / Light Type of study: Prognostic_studies Language: En Journal: ACS Sens Year: 2020 Document type: Article Publication country: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Hydrogen / Light Type of study: Prognostic_studies Language: En Journal: ACS Sens Year: 2020 Document type: Article Publication country: EEUU / ESTADOS UNIDOS / ESTADOS UNIDOS DA AMERICA / EUA / UNITED STATES / UNITED STATES OF AMERICA / US / USA