Whang, Woong-Joo; Yoo, Young-Sik; Kim, Hyun-Seung; Yoon, Geunyoung.
Affiliation
  • Whang WJ; Department of Ophthalmology, Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Yoo YS; Department Ophthalmology, Uijeongbu St. Mary Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu, Korea.
  • Kim HS; Department of Ophthalmology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
  • Yoon G; Flaum Eye Institute, Center for Visual Science, The Institute of Optics, University of Rochester, Rochester, New York, USA. gyoon@ur.rochester.edu.
Sci Rep ; 10(1): 6445, 2020 04 15.
Article in En | MEDLINE | ID: mdl-32296098
The purpose of this study is to investigate the relationships between corneal asphericity and Haigis-L formula prediction errors in routine cataract surgery after refractive surgery for myopic correction. This retrospective study included 102 patients (102 eyes) with a history of previous PRK or LASIK and cataract surgery. Axial length, anterior chamber depth, and central corneal power were measured using the optical biometer. On the anterior corneal surface, Q-value, spherical aberration, and ecentricity at 6.0 and 8.0 mm were measured using a rotating Scheimpflug camera. The postoperative refractive outcome at 6 months, mean error, and mean absolute error were determined. Correlation tests were performed to determine the associations between pre-cataract surgery data and the prediction error. The Q-values for 6.0 and 8.0 mm corneal diameter were 1.57 ± 0.70 (range: 0.03~3.44), and 0.82 ± 0.5 (range: -0.10~-2.66). The spherical aberration for 6.0 and 8.0 mm diameter was 1.16 ± 0.39 µm (range: 0.24~2.08 µm), and 3.69 ± 0.87 µm (range: 0.91~5.91 µm). eccentricity for 6.0 and 8.0 mm diameter was -1.22 ± 0.31 (range: -1.85 to -0.17), and -0.82 ± 0.39 (range: -1.63 to 0.32). The spherical aberration for 8.0 mm cornea diameter showed the highest correlations with the predicion error (r = 0.750; p < 0.001). When the modified Haigis-L formula considering spherical aberration for 8.0 mm produced smaller values in standard deviation of mean error (0.45D versus 0.68D), mean absolute error (0.35D versus 0.55D), and median absolute error (0.31D versus 0.51D) than the Haigis formula. Corneal asphericity influences the predictive accuracy of the Haigis-L formula. The accuracy was enhanced by taking into consideration the corneal spherical aberration for the 8.0 mm zone at pre-cataract surgery state.

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Observational_studies / Prognostic_studies / Risk_factors_studies Language: En Journal: Sci Rep Year: 2020 Document type: Article Country of publication: United kingdom