Your browser doesn't support javascript.
loading
A Method to Assess the Relevance of Nanomaterial Dissolution During Reactivity Testing.
Peijnenburg, Willie J G M; Ruggiero, Emmanuel; Boyles, Matthew; Murphy, Fiona; Stone, Vicki; Elam, Derek A; Werle, Kai; Wohlleben, Wendel.
Affiliation
  • Peijnenburg WJGM; National Institute of Public Health and the Environment (RIVM), Center for Safety of Substances and Products, 3721 MA Bilthoven, The Netherlands.
  • Ruggiero E; Institute of Environmental Sciences (CML), Leiden University, P.O. Box 9518, 2300 RA Leiden, The Netherlands.
  • Boyles M; Department of Material Physics & Analytics & Formulation, BASF SE, Carl­Bosch­Strasse 38, 67056 Ludwigshafen, Germany.
  • Murphy F; Institute of Occupational Medicine (IOM), Research Avenue North, Heriot­Watt University, Midlothian, EH14 4AP Edinburgh, UK.
  • Stone V; Nano Safety Research Group, Heriot­Watt University, EH14 4AS Edinburgh, UK.
  • Elam DA; Nano Safety Research Group, Heriot­Watt University, EH14 4AS Edinburgh, UK.
  • Werle K; Department of Material Physics & Analytics & Formulation, BASF SE, Carl­Bosch­Strasse 38, 67056 Ludwigshafen, Germany.
  • Wohlleben W; Department of Material Physics & Analytics & Formulation, BASF SE, Carl­Bosch­Strasse 38, 67056 Ludwigshafen, Germany.
Materials (Basel) ; 13(10)2020 May 13.
Article in En | MEDLINE | ID: mdl-32414026
ABSTRACT
The reactivity of particle surfaces can be used as a criterion to group nanoforms (NFs) based on similar potential hazard. Since NFs may partially or completely dissolve over the duration of the assays, with the ions themselves inducing a response, reactivity assays commonly measure the additive reactivity of the particles and ions combined. Here, we determine the concentration of ions released over the course of particle testing, and determine the relative contributions of the released ions to the total reactivity measured. We differentiate three classes of reactivity, defined as being A) dominated by particles, B) additive of particles and ions, or C) dominated by ions. We provide examples for each class by analyzing the NF reactivity of Fe2O3, ZnO, CuO, Ag using the ferric reduction ability of serum (FRAS) assay. Furthermore, another two reactivity tests were performed Dichlorodihydrofluorescin diacetate (DCFH2­DA) assay and electron paramagnetic resonance (EPR) spectroscopy. We compare assays and demonstrate that the dose­response may be almost entirely assigned to ions in one assay (CuO in DCFH2­DA), but to particles in others (CuO in EPR and FRAS). When considering this data, we conclude that one cannot specify the contribution of ions to NF toxicity for a certain NF, but only for a certain NF in a specific assay, medium and dose. The extent of dissolution depends on the buffer used, particle concentration applied, and duration of exposure. This culminates in the DCFH2­DA, EPR, FRAS assays being performed under different ion­to­particle ratios, and differing in their sensitivity towards reactions induced by either ions or particles. If applied for grouping, read­across, or other concepts based on the similarity of partially soluble NFs, results on reactivity should only be compared if measured by the same assay, incubation time, and dose range.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Materials (Basel) Year: 2020 Document type: Article Affiliation country: Netherlands

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Materials (Basel) Year: 2020 Document type: Article Affiliation country: Netherlands