Your browser doesn't support javascript.
loading
Optimized microplastic analysis based on size fractionation, density separation and µ-FTIR.
Konechnaya, Olga; Lüchtrath, Sabine; Dsikowitzky, Larissa; Schwarzbauer, Jan.
Affiliation
  • Konechnaya O; Institute of Geology and Geochemistry of Petroleum and Coal, RWTH Aachen University, Lochnerstraße 4-20, 52056 Aachen, Germany E-mail: jan.schwarzbauer@emr.rwth-aachen.de.
  • Lüchtrath S; Institute of Geology and Geochemistry of Petroleum and Coal, RWTH Aachen University, Lochnerstraße 4-20, 52056 Aachen, Germany E-mail: jan.schwarzbauer@emr.rwth-aachen.de.
  • Dsikowitzky L; Institute of Geology and Geochemistry of Petroleum and Coal, RWTH Aachen University, Lochnerstraße 4-20, 52056 Aachen, Germany E-mail: jan.schwarzbauer@emr.rwth-aachen.de.
  • Schwarzbauer J; Institute of Geology and Geochemistry of Petroleum and Coal, RWTH Aachen University, Lochnerstraße 4-20, 52056 Aachen, Germany E-mail: jan.schwarzbauer@emr.rwth-aachen.de.
Water Sci Technol ; 81(4): 834-844, 2020 Feb.
Article in En | MEDLINE | ID: mdl-32460286
ABSTRACT
Microplastic particles have been recognized as global hazardous pollutants in the last few decades pointing to the importance of analyzing and monitoring microplastics, especially in soils and sediments. This study focused on a multi-step approach for microplastic analysis combining grain size fractionation, density separation and identification by µ-FTIR-spectroscopy. Eight widely used polymers (polyethylene (PE), polypropylene (PP), polyvinylchloride (PVC), polystyrol (PS), polyethylenterephthalate (PET), polymethylmethacrylate (PMMA), polyurethane (PU) and polyamide (PA)) were fractionated into four groups of grain sizes (0.1-5 mm). Thereafter, sea sand was spiked with these particles to test a ZnCl2-based density separation for the polymer types and the various grain sizes. The obtained recovery rates were close to 100% showing that ZnCl2-based density separation is suitable to separate the polymer particles from a sandy matrix. This approach was extended on three further environmental matrices and recovery rates for two of them (sandy-silty and fine-grained sediment) also provided reliable values (94-106%). Lastly, the developed multi-step approach was verified by analyzing an environmental sample (sediment from river Tiranë, Albania) characterized by smaller grain size and moderate organic matter content. Identification of two polymer types in different grain size classes verified the suitability of the developed approach for microplastic analyses on particulate matter such as soils and sediments.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Plastics / Water Pollutants, Chemical Language: En Journal: Water Sci Technol Journal subject: SAUDE AMBIENTAL / TOXICOLOGIA Year: 2020 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Plastics / Water Pollutants, Chemical Language: En Journal: Water Sci Technol Journal subject: SAUDE AMBIENTAL / TOXICOLOGIA Year: 2020 Document type: Article