Your browser doesn't support javascript.
loading
Wideband acoustic immitance - Absorbance measurements in ears after stapes surgery.
Niemczyk, Elzbieta; Lachowska, Magdalena; Tataj, Emanuel; Kurczak, Katarzyna; Niemczyk, Kazimierz.
Affiliation
  • Niemczyk E; Department of Otorhinolaryngology Head and Neck Surgery, Medical University of Warsaw, ul. Banacha 1a, 02-097 Warszawa, Poland.
  • Lachowska M; Department of Otorhinolaryngology Head and Neck Surgery, Medical University of Warsaw, ul. Banacha 1a, 02-097 Warszawa, Poland. Electronic address: mlachowska@wum.edu.pl.
  • Tataj E; Department of Medical Informatics and Telemedicine, Medical University of Warsaw, Poland.
  • Kurczak K; Centre for Foreign Languages, Medical University of Warsaw, Poland.
  • Niemczyk K; Department of Otorhinolaryngology Head and Neck Surgery, Medical University of Warsaw, ul. Banacha 1a, 02-097 Warszawa, Poland.
Auris Nasus Larynx ; 47(6): 909-923, 2020 Dec.
Article in En | MEDLINE | ID: mdl-32505608
ABSTRACT

OBJECTIVES:

The study aimed to thoroughly assess absorbance in ears after stapes surgery (stapedotomy/stapedectomy) and how stapes surgery affects wideband acoustic immittance (WAI) metrics.

METHODS:

Eighty-three otosclerotic ears were analyzed pre- and postoperatively. The analysis comprised air-bone gap (ABG) and WAI which included absorbance measurements, resonance frequency assessment, low frequency tympanometry and metrics derived from these measures.

RESULTS:

Absorbance after stapes surgery changed considerably compared to otosclerotic ears before surgery and also differed from normal ears. Absorbance after stapes surgery revealed two significantly different plot types single-low-frequency-peak absorbance and two-peaks absorbance. Stapes surgery reduced resonance frequency in majority of operated ears and increased static compliance in low frequency tympanometry. Static compliance difference was directly proportional to ABG improvement at low frequencies. Postoperative ABG at 250 Hz and 500 Hz was most commonly correlated with postoperative WAI parameters. ABG improvement at 3000 Hz and 4000 Hz was directly proportional to absorbance difference at ~3000 Hz and 4000 Hz. It influenced the width of the postoperative absorbance by shifting both sides of the plot (negative values shift the points of the plot toward lower frequencies) with the correlation being more pronounced in postoperative two-peaks absorbance type ears.

CONCLUSIONS:

Absorbance by itself is not sufficient for assessment of changes to middle function following stapes surgery, and should be complemented with other measures. WAI measurements including absorbance, resonance frequency assessment, low frequency tympanometry, and metrics derived from these measures combined with air-bone gap provide insight into mechano-acoustic changes in the middle-ear system as a result of stapes surgery.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Otosclerosis / Stapes Surgery / Acoustic Impedance Tests / Ear, Middle / Hearing Loss, Conductive Type of study: Diagnostic_studies / Etiology_studies Limits: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: Auris Nasus Larynx Year: 2020 Document type: Article Affiliation country: Poland

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Otosclerosis / Stapes Surgery / Acoustic Impedance Tests / Ear, Middle / Hearing Loss, Conductive Type of study: Diagnostic_studies / Etiology_studies Limits: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: Auris Nasus Larynx Year: 2020 Document type: Article Affiliation country: Poland