Experimental determination of indoor air concentration of 5-chloro-2-methylisothiazol-3(2H)-one/ 2-methylisothiazol-3(2H)-one (CMIT/MIT) emitted by the use of humidifier disinfectant.
Park, Seon-Kyung; Seol, Hwi-Soo; Park, Hee-Jin; Kim, Yoon-Seob; Ryu, Seung-Hun; Kim, Jaehoon; Kim, Suejin; Lee, Jong-Hyeon; Kwon, Jung-Hwan.
Affiliation
  • Park SK; Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, Korea.
  • Seol HS; EH R&C, Environmental Research Center, 410 Jeongseojin-ro, Seo-gu, Incheon, Korea.
  • Park HJ; Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, Korea.
  • Kim YS; Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, Korea.
  • Ryu SH; Humidifier Disinfectant Health Center, National Institute of Environmental Research, 42 Hwangyong-ro, Seo-gu, Incheon, Korea.
  • Kim J; Humidifier Disinfectant Health Center, National Institute of Environmental Research, 42 Hwangyong-ro, Seo-gu, Incheon, Korea.
  • Kim S; Humidifier Disinfectant Health Center, National Institute of Environmental Research, 42 Hwangyong-ro, Seo-gu, Incheon, Korea.
  • Lee JH; EH R&C, Environmental Research Center, 410 Jeongseojin-ro, Seo-gu, Incheon, Korea.
  • Kwon JH; Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, Korea.
Environ Anal Health Toxicol ; 35(2): e2020008, 2020 06.
Article in En | MEDLINE | ID: mdl-32600006
ABSTRACT
A mixture of 5-chloro-2-methylisothiazol-3(2H)-one/2-methylisothiazol-3(2H)-one (CMIT/MIT) had been used as an active ingredient in humidifier disinfectants (HDs). Owing to its high reactivity, the atmospheric concentration of CMIT/MIT, following its use in HD, would be lower than expected assuming that it is removed by ventilation only. In order to evaluate the exposure concentration of CMIT/MIT used as an HD, room-scale chamber studies were conducted under plausible use of three different HD doses at air change rates (ACR) of 0.3, 0.5, and 1.0 h-1. Atmospheric CMIT/MIT was sampled using two serial impingers containing deionized water after the attainment of steady state. Water samples in which CMIT/MIT was dissolved were concentrated using a cosolvent evaporation method with efficiencies of 35.5 and 77.9% for CMIT and MIT, respectively. The estimated air concentration, assuming that all the CMIT/MIT is absorbed in deionized water, increased linearly with increasing emission rate, but was independent of the ACR. This indicates that the removal rate of CMIT/MIT via chemical reactions is more than the removal rate by ventilation. Further investigations on homogeneous and heterogeneous chemical reactions of CMIT/MIT under ambient conditions are necessary to understand the actual exposure concentration of the mixture in HD.