Your browser doesn't support javascript.
loading
Effects on Carbon Molecular Sieve Membrane Properties for a Precursor Polyimide with Simultaneous Flatness and Contortion in the Repeat Unit.
Liang, Jiachen; Wang, Zhenggong; Huang, Menghui; Wu, Shanshan; Shi, Yanshu; Zhang, Yatao; Jin, Jian.
Affiliation
  • Liang J; College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, 215123, P. R. China.
  • Wang Z; College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, 215123, P. R. China.
  • Huang M; College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, 215123, P. R. China.
  • Wu S; College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, 215123, P. R. China.
  • Shi Y; College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, 215123, P. R. China.
  • Zhang Y; School of Chemical Engineering and Energy, Zhengzhou University, Zhengzhou, 450001, P. R. China.
  • Jin J; College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou, 215123, P. R. China.
ChemSusChem ; 13(20): 5531-5538, 2020 Oct 21.
Article in En | MEDLINE | ID: mdl-32696521
ABSTRACT
Carbon molecular sieve (CMS)-based membrane separation is a promising solution for hydrogen separation due to its great advantages on perm-selectivity, thermal stability, and chemical stability. To prepare high-performance CMS membranes, the molecular structure of polymer precursors and their arrangements should be primarily considered. In this work, a benzimidazole-based 6FDA (2,2'-bis(3,4'-dicarboxyphenyl) hexafluoropropane dianhydride)-type polyimide (PABZ-6FDA-PI) is chosen as precursor to prepare the CMS membrane. Effects of chain flatness and contortion in the polyimide precursor on gas-separation performance of CMS membranes were studied in detail by gas adsorption and permeation experiment. The H2 permeability of CMS is up to 9500 Barrer and ideal selectivity of gas pairs of H2 /CH4 and H2 /CO2 is up to 3800 and 13, respectively. The comprehensive performance of hydrogen separation including H2 /CO2 , H2 /N2 , and H2 /CH4 gas pairs is located well above previously reported upper bounds for polymers.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: ChemSusChem Journal subject: QUIMICA / TOXICOLOGIA Year: 2020 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: ChemSusChem Journal subject: QUIMICA / TOXICOLOGIA Year: 2020 Document type: Article