Monitoring antibody response following SARS-CoV-2 infection: diagnostic efficiency of 4 automated immunoassays.
Wolff, Fleur; Dahma, Hafid; Duterme, Cécile; Van den Wijngaert, Sigi; Vandenberg, Olivier; Cotton, Frédéric; Montesinos, Isabel.
Affiliation
  • Wolff F; Department of Clinical Chemistry, Laboratoire Hospitalier Universitaire de Bruxelles (LHUB-ULB), Université Libre de Bruxelles (ULB), Brussels, Belgium. Electronic address: Fleur.wolff@LHUB-ULB.be.
  • Dahma H; Department of Microbiology, Laboratoire Hospitalier Universitaire de Bruxelles (LHUB-ULB), Université Libre de Bruxelles (ULB), Brussels, Belgium.
  • Duterme C; Department of Clinical Chemistry, Laboratoire Hospitalier Universitaire de Bruxelles (LHUB-ULB), Université Libre de Bruxelles (ULB), Brussels, Belgium.
  • Van den Wijngaert S; Department of Microbiology, Laboratoire Hospitalier Universitaire de Bruxelles (LHUB-ULB), Université Libre de Bruxelles (ULB), Brussels, Belgium.
  • Vandenberg O; Innovation and Business Development Unit, LHUB-ULB, Université Libre de Bruxelles, Brussels, Belgium; Division of Infection and Immunity, Faculty of Medical Sciences, University College London, London, United Kingdom.
  • Cotton F; Department of Clinical Chemistry, Laboratoire Hospitalier Universitaire de Bruxelles (LHUB-ULB), Université Libre de Bruxelles (ULB), Brussels, Belgium.
  • Montesinos I; Department of Microbiology, Laboratoire Hospitalier Universitaire de Bruxelles (LHUB-ULB), Université Libre de Bruxelles (ULB), Brussels, Belgium.
Diagn Microbiol Infect Dis ; 98(3): 115140, 2020 Nov.
Article in En | MEDLINE | ID: mdl-32829098
ABSTRACT

INTRODUCTION:

SARS-CoV-2 seroconversion is important for epidemiological studies as well as contact tracing. MATERIAL AND

METHODS:

The antibody response against SARS-CoV-2 was examined in 111 patients with a positive qRT-PCR. Seroconversion was assessed using the Elecsys from Roche, the Liaison S1/S2 IgG from Diasorin, the IgG and IgA from Euroimmun, as well as the VIDAS IgG and IgM. Specificity was estimated based on the measurement of SARS-CoV-2 antibodies in 96 residual samples collected during a non-pandemic period.

RESULTS:

The highest overall sensitivity for detecting seroconversion was obtained using the Elecsys (81.1%), the Euroimmun with a combined detection of IgG/IgA (86.5%), and the VIDAS with a simultaneous measurement of IgG/IgM (78.4%).The Elecsys and the VIDAS IgG/IgM demonstrated a specificity as well as a positive predictive value of 100%.

CONCLUSIONS:

The Elecsys and the VIDAS methods with a combination of IgG/IgM measurement demonstrated a high sensitivity with no false positive results.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pneumonia, Viral / Coronavirus Infections / Clinical Laboratory Techniques / Betacoronavirus / Antibodies, Viral Type of study: Diagnostic_studies / Prognostic_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Diagn Microbiol Infect Dis Year: 2020 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Pneumonia, Viral / Coronavirus Infections / Clinical Laboratory Techniques / Betacoronavirus / Antibodies, Viral Type of study: Diagnostic_studies / Prognostic_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: Diagn Microbiol Infect Dis Year: 2020 Document type: Article
...