Your browser doesn't support javascript.
loading
Predictive factors of truncation artifacts in the arterial phase of Gd-EOB-DTPA-enhanced MRI: a nationwide multicenter study.
Tsurusaki, Masakatsu; Sofue, Keitaro; Onishi, Hiromitsu; Goshima, Satoshi; Higaki, Atsushi; Isoda, Hiroyoshi; Haradome, Hiroki; Ishii, Kazunari; Murakami, Takamichi.
Affiliation
  • Tsurusaki M; Department of Radiology, Faculty of Medicine, Kindai University, 377-2, Ohnohigashi, Osaka-sayama, Osaka, 589-8511, Japan. mtsuru@dk2.so-net.ne.jp.
  • Sofue K; Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan.
  • Onishi H; Department of Radiology, Osaka University Graduate School of Medicine, Suita, Osaka, Japan.
  • Goshima S; Department of Radiology, Gifu University Graduate School of Medicine, Gifu, Gifu, Japan.
  • Higaki A; Department of Radiology, Kawasaki Medical School, Kurashiki, Okayama, Japan.
  • Isoda H; Department of Radiology, Kyoto University Graduate School of Medicine, Kyoto, Kyoto, Japan.
  • Haradome H; Department of Radiology, Kitasato University School of Medicine, Sagamihara, Kanagawa, Japan.
  • Ishii K; Department of Radiology, Faculty of Medicine, Kindai University, 377-2, Ohnohigashi, Osaka-sayama, Osaka, 589-8511, Japan.
  • Murakami T; Department of Radiology, Kobe University Graduate School of Medicine, Kobe, Hyogo, Japan.
Jpn J Radiol ; 39(2): 165-177, 2021 Feb.
Article in En | MEDLINE | ID: mdl-33025339
ABSTRACT

PURPOSE:

To identify predictive factors for truncation artifacts (TAs) in the arterial phase of Gd-EOB-DTPA-enhanced MRI in a multicenter study in Japan. MATERIALS AND

METHODS:

Data on patient factors (age, sex, weight, presence of viral hepatitis, and other conditions) and imaging parameters (e.g., triggering, voxel size, matrix, k-space ordering, acquisition time, reduction factor, flip angle, fat suppression, field strength, injection rate, and saline volume) were obtained. Univariate and multivariate analyses were performed to investigate the correlation of these parameters.

RESULTS:

We evaluated 1444 patients from 43 institutions who were scanned using GE, Siemens, Philips, or Toshiba MRI equipment (501, 354, 349, and 240 patients, respectively). The total incidence of TAs was 12.5% (17.2, 3.6, 15.7, and 12.1%, respectively). The matrix [odds ratio (OR) 0.13], flip angle (OR 5.77), use of fat suppression (OR 0.106), and field strength (OR 0.092) used in the Philips equipment significantly increased the incidence of TAs in MRI examination.

CONCLUSIONS:

The incidence of TAs in the arterial phase is influenced by several patient factors and imaging parameters. Especially, Siemens and Toshiba equipment had a significantly lower frequency of TAs. This indicates that such vendor-specific technology used in the dynamic sequence may have a TA-resistant effect.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Magnetic Resonance Imaging / Contrast Media / Gadolinium DTPA / Liver Type of study: Clinical_trials / Prognostic_studies / Risk_factors_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Jpn J Radiol Journal subject: DIAGNOSTICO POR IMAGEM / RADIOLOGIA / RADIOTERAPIA Year: 2021 Document type: Article Affiliation country: Japan

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Magnetic Resonance Imaging / Contrast Media / Gadolinium DTPA / Liver Type of study: Clinical_trials / Prognostic_studies / Risk_factors_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Jpn J Radiol Journal subject: DIAGNOSTICO POR IMAGEM / RADIOLOGIA / RADIOTERAPIA Year: 2021 Document type: Article Affiliation country: Japan