Percutaneous left ventricular assist support is associated with less pulmonary congestion and lower rate of pneumonia in patients with cardiogenic shock.
Open Heart
; 7(2)2020 11.
Article
in En
| MEDLINE
| ID: mdl-33132209
OBJECTIVES: The aim of this study was to investigate the impact of acute left ventricular unloading by percutaneous left ventricular assist device on pulmonary congestion and pneumonia in patients with cardiogenic shock (CS). METHODS: In this retrospective study, we analysed patients with CS who received the Impella percutaneous left ventricular assist device (n=50) compared with those who received intra-aortic balloon pump (IABP) support (n=50). Pulmonary congestion was longitudinally assessed while on support by calculating characteristic findings on the chest X-ray using the Halperin score. The rate of pneumonia and early mortality were assessed as a secondary endpoint. RESULTS: The groups (Impella vs IABP) did not differ in terms of age, Sequential Organ Failure Assessment (SOFA) score, Acute Physiology, Chronic Health Evaluation (APACHE) II score or serum lactate levels. Pulmonary congestion decreased in patient treated with Impella at each time point postimplantation. No change in congestion status was observed in patients supported with IABP. Multivariate analysis indicated Impella support as an independent predictor for pulmonary decongestion (OR 4.06, 95% CI 1.15 to 14.35, p=0.030). The rate of early pneumonia was lower in the Impella group compared with the IABP group (54% vs 74%, p=0.037). Failure of pulmonary decongestion during mechanical circulatory support independently predicted early pneumonia (OR 0.28, 95% CI 0.12 to 0.70, p=0.006). CONCLUSION: Pulmonary decongestion may facilitate treatment of pneumonia in patients with CS. Left ventricular unloading by Impella device might support pulmonary decongestion, although a larger prospective trial in this patient population is required.
Key words
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Pneumonia
/
Pulmonary Edema
/
Shock, Cardiogenic
/
Heart-Assist Devices
/
Ventricular Function, Left
/
Prosthesis Implantation
/
Intra-Aortic Balloon Pumping
Type of study:
Diagnostic_studies
/
Etiology_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limits:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Language:
En
Journal:
Open Heart
Year:
2020
Document type:
Article
Affiliation country:
Germany
Country of publication:
United kingdom