Your browser doesn't support javascript.
loading
Orientation-specific long-term neural adaptation of the visual system in keratoconus.
Hastings, Gareth D; Schill, Alexander W; Hu, Chuan; Coates, Daniel R; Applegate, Raymond A; Marsack, Jason D.
Affiliation
  • Hastings GD; College of Optometry, University of Houston, TX, USA. Electronic address: gdhastings1@gmail.com.
  • Schill AW; College of Optometry, University of Houston, TX, USA.
  • Hu C; College of Optometry, University of Houston, TX, USA.
  • Coates DR; College of Optometry, University of Houston, TX, USA.
  • Applegate RA; College of Optometry, University of Houston, TX, USA.
  • Marsack JD; College of Optometry, University of Houston, TX, USA.
Vision Res ; 178: 100-111, 2021 01.
Article in En | MEDLINE | ID: mdl-33190099
ABSTRACT
Eyes with the corneal ectasia keratoconus have performed better than expected (e.g. visual acuity) given their elevated levels of higher-order aberrations that cause rotationally asymmetric retinal blur. Adapted neural processing has been suggested as an explanation but has not been measured across multiple meridional orientations. Using a custom Maxwellian-view laser interferometer to bypass ocular optics, sinusoidal grating neural contrast sensitivity was measured in six eyes (three subjects) with keratoconus and four typical eyes (two subjects) at six spatial frequencies and eight orientations using a two-interval forced-choice paradigm. Total measurement duration was 24 to 28 hours per subject. Neural contrast sensitivity functions of typical eyes agreed with literature and generally showed the oblique effect on a linear-scale and rotational symmetry on a log-scale (rotational symmetry was quantified as the ratio of the minor and major radii of an ellipse fit to all orientations within each spatial frequency; typical eye mean 0.93, median 0.93; where a circle = 1). Mean sensitivities of eyes with keratoconus were 20% to 60% lower (at lower and higher spatial frequencies respectively) than typical eyes. Orientation-specific neural contrast sensitivity functions in keratoconus showed substantial rotational asymmetry (ellipse radii ratio mean 0.84; median 0.86) and large meridional reductions. The visual image quality metric VSX was used with a permutation test to combine the asymmetric optical aberrations of the eyes with keratoconus and their measured asymmetric neural functions, which illustrated how the neural sensitivities generally mitigated the detrimental effects of the optics.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Keratoconus Limits: Humans Language: En Journal: Vision Res Year: 2021 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Keratoconus Limits: Humans Language: En Journal: Vision Res Year: 2021 Document type: Article