Your browser doesn't support javascript.
loading
Validated HPLC-MS/MS method for quantitation of AMG 510, a KRAS G12C inhibitor, in mouse plasma and its application to a pharmacokinetic study in mice.
Madhyastha, Naveena; Samantha, Swapan Kumar; Dittakavi, Sreekanth; Markose, Meenu; Mallurwar, Sadanand Rangnathrao; Zainuddin, Mohd; Mullangi, Ramesh.
Affiliation
  • Madhyastha N; Medicinal Chemistry, Jubilant Biosys Ltd, Bangalore, India.
  • Samantha SK; Medicinal Chemistry, Jubilant Biosys Ltd, Bangalore, India.
  • Dittakavi S; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Bangalore, India.
  • Markose M; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Bangalore, India.
  • Mallurwar SR; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Bangalore, India.
  • Zainuddin M; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Bangalore, India.
  • Mullangi R; Drug Metabolism and Pharmacokinetics, Jubilant Biosys Ltd, Bangalore, India.
Biomed Chromatogr ; 35(4): e5043, 2021 Apr.
Article in En | MEDLINE | ID: mdl-33283304
ABSTRACT
AMG 510 is the first-in-class KRASG12C inhibitor, currently in phase 2 clinical trials as an orphan drug to treat non-small cell lung cancer patients. We developed and validated a sensitive, selective, and high-throughput HPLC-MS/MS method for the quantitation of AMG 510 in mouse plasma per the regulatory guideline of the US Food and Drug and Administration. AMG 510 and the IS (MRTX-1257) were extracted from mouse plasma using tert-butyl methyl ether and chromatographed using an isocratic mobile phase (0.2% formic acidacetonitrile; 2575, v/v) at a flow rate of 0.65 mL/min on an Atlantis dC18 column. AMG 510 and the IS eluted at ~0.95 and 0.73 min, respectively. AMG 510 and the IS were detected by positive electrospray ionization in multiple reaction monitoring using transition pair (Q1 → Q3) m/z 561.1 → 134.1 and m/z 566.5 → 98.2, respectively. Excellent linearity was achieved in the concentration range of 1.08-5040 ng/mL (r > 0.0996). No matrix effect and carryover were observed. Intra- and inter-day accuracies and precisions were within the acceptance range. AMG 510 was demonstrated to be stable under the tested storage conditions. This novel method has been applied to a pharmacokinetic study in mice.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Piperazines / Pyridines / Pyrimidines / Chromatography, High Pressure Liquid / Tandem Mass Spectrometry Type of study: Diagnostic_studies / Guideline / Prognostic_studies Limits: Animals Language: En Journal: Biomed Chromatogr Year: 2021 Document type: Article Affiliation country: India Publication country: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Piperazines / Pyridines / Pyrimidines / Chromatography, High Pressure Liquid / Tandem Mass Spectrometry Type of study: Diagnostic_studies / Guideline / Prognostic_studies Limits: Animals Language: En Journal: Biomed Chromatogr Year: 2021 Document type: Article Affiliation country: India Publication country: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM