Your browser doesn't support javascript.
loading
Creation of an ex-vivo bovine kidney flow model for testing embolic agents: work in progress.
Garza, Luis; Bitar, Ryan; O'Donnell, Barrett; Parker, Matthew; Ortiz, Carlos; Hyman, Charles; Walker, John; Song, Ho-Young; Lopera, Jorge.
Affiliation
  • Garza L; Long School of Medicine, University of Texas Health Science Center, 7703 Floyd Curl Drive San Antonio, San Antonio, TX, 78229, USA.
  • Bitar R; Long School of Medicine, University of Texas Health Science Center, 7703 Floyd Curl Drive San Antonio, San Antonio, TX, 78229, USA.
  • O'Donnell B; Department of Radiology, University of Texas Health Science Center, San Antonio, TX, USA.
  • Parker M; Department of Radiology, University of Texas Health Science Center, San Antonio, TX, USA.
  • Ortiz C; Department of Radiology, University of Texas Health Science Center, San Antonio, TX, USA.
  • Hyman C; Department of Radiology, University of Texas Health Science Center, San Antonio, TX, USA.
  • Walker J; Department of Radiology, University of Texas Health Science Center, San Antonio, TX, USA.
  • Song HY; Department of Radiology, University of Texas Health Science Center, San Antonio, TX, USA.
  • Lopera J; Department of Diagnostic Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
CVIR Endovasc ; 4(1): 20, 2021 Feb 03.
Article in En | MEDLINE | ID: mdl-33534088
ABSTRACT

OBJECTIVES:

To develop an ex- vivo perfusion flow model using a bovine kidney for future testing of embolic agents in an inexpensive and easy way.

METHODS:

Six bovine adult kidneys were used for this study. Kidneys were cannulated and perfused via a roller pump. Three embolic agents, coils, Gelfoam, and a glue mixture of Histoacryl + Lipiodol, were deployed by targeting three secondary segmental arteries per kidney via a 5Fr catheter under fluoroscopic guidance. Cannulation time, success rate of segmental artery selection and embolic agent deployment, total operational time, and fluoroscopy dose were recorded.

RESULTS:

Average kidney weight was 0.752 +/- 0.094 kg. All six bovine kidneys were successfully cannulated in 21.6 min +/- 3.0 min. Deployment of coils and glue was achieved in every case (12/12); however, Gelfoam injection was not successful in one instance (5/6, 83%). Coil deployment demonstrated no embolic effect while Gelfoam and glue injections demonstrated decreased distal contrast filling post-embolization. Mean dose area product was 12.9 ± 1.8 Gy·cm2, fluoroscopy time was 10 ± 4 min and operational time was 27 ± 8 min.

CONCLUSIONS:

We describe the creation of an ex vivo bovine kidney flow model for the preclinical evaluation of different embolic materials. The flow model can be modified to provide extensive bench testing and it is a promising tool for hands -on training in basic and advanced embolization techniques .
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: CVIR Endovasc Year: 2021 Document type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: CVIR Endovasc Year: 2021 Document type: Article Affiliation country: United States