Your browser doesn't support javascript.
loading
A modified clot-based assay to measure negatively charged procoagulant phospholipids.
Ramberg, Cathrine; Jamaly, S; Latysheva, N; Wilsgård, L; Sovershaev, T; Snir, O; Hansen, J-B.
Affiliation
  • Ramberg C; K.G. Jebsen Thrombosis Research and Expertise Centre (TREC), Department of Clinical Medicine, UiT-The Arctic University of Norway, 9037, Tromsø, Norway. cathrine.c.ramberg@uit.no.
  • Jamaly S; K.G. Jebsen Thrombosis Research and Expertise Centre (TREC), Department of Clinical Medicine, UiT-The Arctic University of Norway, 9037, Tromsø, Norway.
  • Latysheva N; K.G. Jebsen Thrombosis Research and Expertise Centre (TREC), Department of Clinical Medicine, UiT-The Arctic University of Norway, 9037, Tromsø, Norway.
  • Wilsgård L; K.G. Jebsen Thrombosis Research and Expertise Centre (TREC), Department of Clinical Medicine, UiT-The Arctic University of Norway, 9037, Tromsø, Norway.
  • Sovershaev T; K.G. Jebsen Thrombosis Research and Expertise Centre (TREC), Department of Clinical Medicine, UiT-The Arctic University of Norway, 9037, Tromsø, Norway.
  • Snir O; K.G. Jebsen Thrombosis Research and Expertise Centre (TREC), Department of Clinical Medicine, UiT-The Arctic University of Norway, 9037, Tromsø, Norway.
  • Hansen JB; K.G. Jebsen Thrombosis Research and Expertise Centre (TREC), Department of Clinical Medicine, UiT-The Arctic University of Norway, 9037, Tromsø, Norway.
Sci Rep ; 11(1): 9341, 2021 04 29.
Article in En | MEDLINE | ID: mdl-33927323
Growing evidence supports a role for extracellular vesicles (EVs) in haemostasis and thrombosis due to exposure of negatively charged procoagulant phospholipids (PPL). Current commercial PPL-dependent clotting assays use chemically phospholipid depleted plasma to measure PPL activity. The purpose of our study was to modify the PPL assay by substituting the chemically phospholipid depleted plasma with PPL depleted plasma obtained by ultracentrifugation This in order to get readily access to a sensitive and reliable assay to measure PPL activity in human plasma and cell supernatants. The performance of the assay was tested, including the influence of individual coagulation factors and postprandial lipoproteins and compared to a commercial PPL assay (STA-Procoag-PPL). The two PPL assays displayed similar sensitivity to exogenously added standardized phospholipids. The PPL activity measured by the modified assay strongly correlates with the results from the commercial assay. The intraday- and between-days coefficients of variation ranged from 2-4% depending on the PPL activity in the sample. The modified PPL assay was insensitive to postprandial lipoprotein levels in plasma, as well as to tissue factor (TF) positive EVs from stimulated whole blood. Our findings showed that the modified assay performed equal to the comparator, and was insensitive to postprandial lipoproteins and TF+ EVs.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Phospholipids / Blood Coagulation Tests Limits: Humans Language: En Journal: Sci Rep Year: 2021 Document type: Article Affiliation country: Norway Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Phospholipids / Blood Coagulation Tests Limits: Humans Language: En Journal: Sci Rep Year: 2021 Document type: Article Affiliation country: Norway Country of publication: United kingdom