Your browser doesn't support javascript.
loading
Longitudinal stability of a multimodal visco-elastic polyacrylamide gel phantom for magnetic resonance and ultrasound shear-wave elastography.
Usumura, Masashi; Kishimoto, Riwa; Ishii, Koki; Hotta, Eika; Kershaw, Jeff; Higashi, Tatsuya; Obata, Takayuki; Suga, Mikio.
Affiliation
  • Usumura M; Department of Medical Engineering, Graduate School of Science and Engineering, Chiba University, Chiba, Japan.
  • Kishimoto R; QST Hospital, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan.
  • Ishii K; Department of Medical Engineering, Graduate School of Science and Engineering, Chiba University, Chiba, Japan.
  • Hotta E; QST Hospital, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan.
  • Kershaw J; Applied MRI Research, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan.
  • Higashi T; Department of Molecular Imaging and Theranostics, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan.
  • Obata T; Applied MRI Research, National Institute of Radiological Sciences, National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan.
  • Suga M; Center for Frontier Medical Engineering, Chiba University, Chiba, Japan.
PLoS One ; 16(5): e0250667, 2021.
Article in En | MEDLINE | ID: mdl-34019551
ABSTRACT
We evaluated the long-term stability of a newly developed viscoelastic phantom made of polyacrylamide (PAAm) gel for magnetic resonance elastography (MRE) and ultrasound-based shear-wave elastography (US SWE). The stiffness of the cylindrical phantom was measured at 0, 13 and 18 months. Storage and loss moduli were measured with MRE, and shear-wave speed (SWS) was measured with US SWE. Long-term stability was evaluated in accordance with the Quantitative Imaging Biomarker Alliance (QIBA) profiles for each modality. The initial storage and loss moduli of the phantom were 5.01±0.22 and 1.11±0.15 respectively, and SWS was 2.57±0.04 m/s. The weight of the phantom decreased by 0.6% over the 18 months. When measured with MRE, the stiffness of the phantom decreased and changes to the storage and loss moduli were -3.0% and -4.6% between 0 and 13 months, and -4.3% and 0.0% between 0 and 18 months. The US measurements found that SWS decreased by 2.4% over the first 13 months and 3.6% at 18 months. These changes were smaller than the tolerances specified in the QIBA profiles, so the viscoelastic PAAm gel phantom fulfilled the condition for long-term stability. This new phantom has the potential to be used as a quality assurance and quality control phantom for MRE and US SWE.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Acrylic Resins / Magnetic Resonance Imaging / Phantoms, Imaging / Elasticity / Elasticity Imaging Techniques Type of study: Diagnostic_studies / Observational_studies Language: En Journal: PLoS One Journal subject: CIENCIA / MEDICINA Year: 2021 Document type: Article Affiliation country: Japan

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Acrylic Resins / Magnetic Resonance Imaging / Phantoms, Imaging / Elasticity / Elasticity Imaging Techniques Type of study: Diagnostic_studies / Observational_studies Language: En Journal: PLoS One Journal subject: CIENCIA / MEDICINA Year: 2021 Document type: Article Affiliation country: Japan