Your browser doesn't support javascript.
loading
Biodegradable polymer drug-eluting stents versus durable polymer drug-eluting stents for percutaneous coronary intervention: a contemporary registry-based analysis.
Levi, Amos; Kheifets, Mark; Bental, Tamir; Perl, Leor; Codner, Pablo; Witberg, Guy; Talmor-Barkan, Yeela; Landes, Uri; Samara, Abed; Greenberg, Gabriel; Erez, Aharon; Vaknin-Assa, Hanna; Kornowski, Ran.
Affiliation
  • Levi A; Department of Cardiology, Rabin Medical Center, Petach Tikva and the Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
Coron Artery Dis ; 33(2): 105-113, 2022 03 01.
Article in En | MEDLINE | ID: mdl-34074911
ABSTRACT

AIMS:

We aimed to compare the long-term outcomes of patients undergoing percutaneous coronary intervention (PCI) with biodegradable polymer drug-eluting stents (BP-DES) versus durable polymer drug-eluting stents (DP-DES). METHODS AND

RESULTS:

Among 11 517 PCIs with second-generation DES performed in our institution between 2007 and 2019, we identified 8042 procedures performed using DP-DES and 3475 using BP-DES. The primary outcome was target lesion failure, the composite target lesion revascularization (TLR), target vessel myocardial infarction and death. Propensity score matching was used to create a well-balanced cohort. Mean follow-up was 4.8 years. Of the 3413 matched pairs, 21% were females, and the mean age was 66 years. At 1 year, the primary outcome occurred in 8.3% patients versus 7.1% (P = 0.07), and TLR rate was 3% versus 2% (P = 0.006) in patients with DP-DES and BP-DES respectively. Within 5 years, the primary outcome occurred in 23.1% versus 23.4% (P = 0.44), and the rate of TLR was 7.2% versus 6.5% (P = 0.07) in patients with DP-DES and BP-DES, respectively.

CONCLUSION:

Similar rates of the composite outcome were observed throughout the entire follow-up. Target lesion revascularization rates were lower in the BP-DES group at 1-year but equalized within 5 years.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Durable Medical Equipment / Absorbable Implants / Drug-Eluting Stents Type of study: Prognostic_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Coron Artery Dis Journal subject: ANGIOLOGIA / CARDIOLOGIA Year: 2022 Document type: Article Affiliation country: Israel Publication country: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Durable Medical Equipment / Absorbable Implants / Drug-Eluting Stents Type of study: Prognostic_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Coron Artery Dis Journal subject: ANGIOLOGIA / CARDIOLOGIA Year: 2022 Document type: Article Affiliation country: Israel Publication country: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM