[Clinical application value of transthoracic echocardiography during perioperative period in patients undergoing left ventricular assist device implantation].
Zhonghua Xin Xue Guan Bing Za Zhi
; 49(6): 610-614, 2021 Jun 24.
Article
in Zh
| MEDLINE
| ID: mdl-34126729
ABSTRACT
Objective:
To observe the changes of parameters derived from transthoracic echocardiography (TTE) before and after left ventricular assist device (LVAD) implantation, and to evaluate the clinical value of TTE in the perioperative period of LVAD implantation.Methods:
This is a retrospective study. The data of patients who underwent LVAD implantation in Fuwai Hospital from January 2018 to December 2020 were analyzed retrospectively. The TTE parameters, N-terminal pro-B-type natriuretic peptide (NT-proBNP) and total bilirubin (TBil) before and 1 month after LVAD implantation were collected and analyzed.Results:
A total of 12 male patients undergoing LVAD implantation were included in this study. The mean age was (43.3±8.6) years. The left atrial volume index ((41.4±12.8)ml/m2 vs. (74.9±30.7)ml/m2, P<0.001), left ventricular end-diastolic volume index ((152.1±35.3)ml/m2 vs. (205.5±35.7)ml/m2, P<0.001), left ventricular end-systolic volume index ((112.5±27.9)ml/m2 vs. (155.1±29.1)ml/m2, P<0.001), right atrial diameter index ((23.7±3.5)mm/m2 vs. (27.2±5.8)mm/m2, P=0.023), right ventricular internal diameter at end-diastole ((24.6±2.7)mm vs. (30.0±4.8)mm, P<0.001), tricuspid annular plane systolic excursion ((11.5±2.9)mm vs. (14.6±2.8)mm, P=0.007), systolic pulmonary arterial pressure ((29.2±4.8) mmHg vs. (55.1±19.3) mmHg, P<0.001, 1 mmHg=0.133 kPa) were significantly reduced at 1 month post LVAD implantation as compared to before LVAD implantation. The aortic sinus diameter ((33.8±4.7)mm vs. (31.6±5.1)mm, P=0.007), left ventricular ejection fraction ((26.3±3.0)% vs. (23.8±4.4)%, P=0.016), right ventricular fractional area change ((31.0±8.6)% vs. (23.8±5.5)%, P=0.004) at 1 month post LVAD implantation were significantly higher than before LVAD implantation. The degree of mitral and tricuspid regurgitation decreased, and the inspiratory collapse rate of inferior vena cava increased (all P<0.05). NT-proBNP ((1 418.4±812.6)ng/L vs. (5 097.5±3 940.4)ng/L, P=0.004) and TBil ((12.4±5.4)µmol/L vs. (27.5±14.0)µmol/L, P=0.001) decreased significantly at 1 month post LVAD implantation.Conclusions:
TTE results show that LVAD could effectively relieve left ventricular load and improve right ventricular function. TTE can monitor the cardiac structural and functional changes during the perioperative period of LVAD implantation, and provide the imaging evidence for clinical evaluation of the therapeutic effect of LVAD.
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Heart-Assist Devices
/
Heart Failure
Type of study:
Observational_studies
Limits:
Adult
/
Humans
/
Male
/
Middle aged
Language:
Zh
Journal:
Zhonghua Xin Xue Guan Bing Za Zhi
Year:
2021
Document type:
Article
Affiliation country:
China