Your browser doesn't support javascript.
loading
Time domain DNP at 1.2 T.
Can, T V; Tan, K O; Yang, C; Weber, R T; Griffin, R G.
Affiliation
  • Can TV; Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, United States; Department of Chemistry, Massachusetts Institute of Technology, Cambridge, MA 02139, United States.
  • Tan KO; Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, United States; Department of Chemistry, Massachusetts Institute of Technology, Cambridge, MA 02139, United States.
  • Yang C; Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, United States; Department of Chemistry, Massachusetts Institute of Technology, Cambridge, MA 02139, United States.
  • Weber RT; Bruker BioSpin Corporation, Billerica, MA 01821, United States.
  • Griffin RG; Francis Bitter Magnet Laboratory, Massachusetts Institute of Technology, Cambridge, MA 02139, United States; Department of Chemistry, Massachusetts Institute of Technology, Cambridge, MA 02139, United States.
J Magn Reson ; 329: 107012, 2021 08.
Article in En | MEDLINE | ID: mdl-34186299
ABSTRACT
We present the results of an experimental pulsed DNP study at 1.2 T (33.5 GHz/51 MHz electron and 1H Larmor frequencies, respectively). The results include a comparison of constant-amplitude NOVEL (CA-NOVEL), ramped-amplitude NOVEL (RA-NOVEL) and the frequency-swept integrated solid effect (FS-ISE) experiments all of which were performed at the NOVEL matching condition, ω1S=ω0I, where ω1S is the electron Rabi frequency andω0I the proton Larmor frequency. To the best of our knowledge, this is the first pulsed DNP study carried out at field higher than X-band (0.35 T) using the NOVEL condition. A combination of high microwave power (∼150 W) and a microwave cavity with a high Q (∼500) allowed us to satisfy the NOVEL matching condition. We also observed stretched solid effect (S2E) contributions in the Zeeman field profiles when chirped pulses are applied. Furthermore, the high quality factor of the cavity limits the concentration of the radical to ∼5 mM and generates a hysteresis in the FS-ISE experiments. Nevertheless, we observe very high DNP enhancements that are comparable to the results at X-band. These promising outcomes suggest the importance of further studies at even higher fields that delineate the instrumentation and methods required for time domain DNP.