High prevalence of xylazine among fentanyl screen-positive urines from hospitalized patients, Philadelphia, 2021.
Korn, Warren R; Stone, Matthew D; Haviland, Kaddie L; Toohey, Joanne M; Stickle, Douglas F.
Affiliation
  • Korn WR; Department of Pathology, Jefferson University Hospital, Philadelphia, PA, USA.
  • Stone MD; Department of Pathology, Jefferson University Hospital, Philadelphia, PA, USA.
  • Haviland KL; Department of Pathology, Jefferson University Hospital, Philadelphia, PA, USA.
  • Toohey JM; Department of Pathology, Jefferson University Hospital, Philadelphia, PA, USA.
  • Stickle DF; Department of Pathology, Jefferson University Hospital, Philadelphia, PA, USA. Electronic address: douglas.stickle@jefferson.edu.
Clin Chim Acta ; 521: 151-154, 2021 Oct.
Article in En | MEDLINE | ID: mdl-34265257
BACKGROUND: Xylazine is an α-2 adrenoreceptor agonist used as a sedative/analgesic in veterinary medicine. Xylazine is known to be present within the street supply of opiates in urban Philadelphia. Medical staff at our hospital asked if we could test for xylazine in fentanyl screen-positive urine samples. We developed an LC-MS/MS assay for this purpose, and determined prevalence of xylazine among fentanyl screen-positive urine samples at our hospital. METHODS: The LC-MS/MS assay utilized d5-norfentanyl as internal standard (IS). One hundred microliter samples were extracted with 200 µl of MeOH/IS. LC was performed using a Phenomenex Kinetix C18 column (100 A, 5 µm, 50 × 4.6 mm) at 40 °C. Time-variable mobile phases (A = H2O, 0.1% formic acid; B = MeOH, 0.1% formic acid) were used at a fixed flow rate of 0.5 ml/min. MS/MS used positive electrospray ionization, monitoring m/z transitions of 221 > 164 for xylazine (primary), 221 > 90 for xylazine (qualifier), and 238 > 84 for d5-norfentanyl (IS). Retention time was 3.9 min for both xylazine and IS. RESULTS: Calibration curve was linear (0-500 ng/ml; r > 0.99). Inter-assay CVs (n = 20) were 5.2% (18 ng/ml) and 6.6% (95 ng/ml). Lower limit of detection was set at 10 ng/ml (CV = 15%). Among 81 urine samples that were screen-positive for fentanyl (Ark Diagnostics immunoassay), 63 (78%) were positive for xylazine (>10 ng/ml). CONCLUSIONS: By LC-MS/MS, there was high prevalence (78%) of xylazine in fentanyl screen-positive urine samples submitted to the laboratory. Because α-2 adrenoreceptor agonists may be used in treatment of opioid addiction, knowledge of xylazine exposure may be clinically useful to guide patient management.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Xylazine / Tandem Mass Spectrometry Type of study: Prevalence_studies / Risk_factors_studies Limits: Humans Country/Region as subject: America do norte Language: En Journal: Clin Chim Acta Year: 2021 Document type: Article Affiliation country: United States Country of publication: Netherlands

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Xylazine / Tandem Mass Spectrometry Type of study: Prevalence_studies / Risk_factors_studies Limits: Humans Country/Region as subject: America do norte Language: En Journal: Clin Chim Acta Year: 2021 Document type: Article Affiliation country: United States Country of publication: Netherlands