Your browser doesn't support javascript.
loading
Assessment of a Novel, 22-lead Mobile Electrocardiogram in Elite, Adolescent Footballers.
Johnson, Harvey; Duarte, Nuno; Ryding, Diane; Perry, Dave; McNally, Steve; Stuart, A Graham; Williams, Craig Anthony; Pieles, Guido.
Affiliation
  • Johnson H; Bristol Medical School, University of Bristol, Bristol, United Kingdom of Great Britain and Northern Ireland.
  • Duarte N; Cardiac Physiology Department, Bristol Royal Hospital for Children, Bristol, United Kingdom of Great Britain and Northern Ireland.
  • Ryding D; Physiotherapy Department, Manchester United Ltd, Manchester, United Kingdom of Great Britain and Northern Ireland.
  • Perry D; Football Medicine & Science Department, Manchester United Ltd, Manchester, United Kingdom of Great Britain and Northern Ireland.
  • McNally S; Football Medicine & Science Department, Manchester United Ltd, Manchester, United Kingdom of Great Britain and Northern Ireland.
  • Stuart AG; Congenital Heart Unit, Bristol Heart Institute, Upper Maudlin Street, National Institute for Health Research Cardiovascular Biomedical Research Centre, Bristol, United Kingdom of Great Britain and Northern Ireland.
  • Williams CA; Children's Health & Exercise Research Centre, University of Exeter, Exeter, United Kingdom of Great Britain and Northern Ireland.
  • Pieles G; Congenital Heart Unit, Bristol Heart Institute, Upper Maudlin Street, National Institute for Health Research Cardiovascular Biomedical Research Centre, Bristol, United Kingdom of Great Britain and Northern Ireland.
Int J Sports Med ; 43(3): 245-253, 2022 Mar.
Article in En | MEDLINE | ID: mdl-34388845
The 12-lead electrocardiogram is a key component of cardiac screening in elite adolescent footballers. Current technology hampers mobile electrocardiogram monitoring that could reduce the time-to-diagnosis in symptomatic athletes. Recently, a 22-lead mobile electrocardiogram monitor, CardioSecur (Personal MedSystems GmbH), has been approved for use in adults. In this study, the differences in parameter accuracy between CardioSecur's 22-lead electrocardiogram and the gold standard 12-lead electrocardiogram were assessed in elite adolescent footballers (n=31) using Bland-Altman and paired t-tests/Wilcoxon analysis. Agreement between the two devices was clinically acceptable for heart rate (bias=- 0.633 bpm), PR Interval (bias=- 1.73 ms), Bazzett's corrected QTc interval (bias=2.03 ms), T-wave axis (bias=6.55°), P-wave duration (bias=- 0.941 ms), Q-wave amplitude (bias=0.0195 mV), Q-wave duration (bias=1.98 ms), rhythm (bias=0.0333), ST-segment (bias=- 0.0629), J-point analysis (bias=- 0.01) and extended T wave and QRS duration analysis. Unsatisfactory agreement was observed in QRS axis (bias=- 19.4°), P-wave axis (bias=- 0.670°), QRS amplitude (bias=- 0.660 mV), P-wave amplitude (bias=0.0400 mV) and T-wave amplitude (bias=- 0.0675 mV). CardioSecur's 22-lead electrocardiogram agrees with the gold standard in rhythm, durations, T-wave determination in all leads assessed, permitting its use in adolescent footballers for immediate pitch- or track-side analysis.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arrhythmias, Cardiac / Electrocardiography Limits: Adolescent / Adult / Humans Language: En Journal: Int J Sports Med Year: 2022 Document type: Article Country of publication: Germany

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Arrhythmias, Cardiac / Electrocardiography Limits: Adolescent / Adult / Humans Language: En Journal: Int J Sports Med Year: 2022 Document type: Article Country of publication: Germany