Your browser doesn't support javascript.
loading
Redundant laboratory testing on referral from general practice to the outpatient clinic: a post-hoc analysis.
Vrijsen, Bram El; Ten Berg, Maarten J; van Solinge, Wouter W; Westerink, Jan.
Affiliation
  • Vrijsen BE; Department of Internal Medicine, Division Internal Medicine and Dermatology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands b.e.l.vrijsen@umcutrecht.nl.
  • Ten Berg MJ; Central Diagnostic Laboratory, Division Laboratories, Pharmacy and Biomedical Genetics, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.
  • van Solinge WW; Central Diagnostic Laboratory, Division Laboratories, Pharmacy and Biomedical Genetics, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.
  • Westerink J; Department of Internal Medicine, Division Internal Medicine and Dermatology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands.
BJGP Open ; 6(1)2022 Mar.
Article in En | MEDLINE | ID: mdl-34620597
ABSTRACT

BACKGROUND:

Inappropriately repeated laboratory testing is a commonly occurring problem. However, this has not been studied extensively in the outpatient clinic after referral by GPs.

AIM:

The aim of this study was to investigate how often laboratory tests ordered by the GP were repeated on referral to the outpatient clinic, and how many of the normal test results remained normal on repetition. DESIGN &

SETTING:

This is a post-hoc analysis of a study on laboratory testing strategies in patients newly referred to the outpatient clinic between April 2015 and April 2017.

METHOD:

All patients who had a referral letter including laboratory test results ordered by the GP were included. These results were compared with the laboratory test results ordered in the outpatient clinic.

RESULTS:

Data were available for 295 patients, 191 of which had post-visit testing done. In this group, 56% of tests ordered by the GP were repeated. Tests with abnormal results were repeated more frequently than tests with normal results (65% versus 53%; P<0.001). A longer test interval was associated with slightly smaller odds of tests being repeated (odds ratio [OR] 0.97, 95% confidence interval [CI] = 0.95 to 0.99; P = 0.003). Of the tests with normal test results that were repeated, 90% remained normal. This was independent of testing interval or testing strategy.

CONCLUSION:

Laboratory tests ordered by the GP are commonly repeated on referral to the outpatient clinic. The number of test results remaining normal on repetition suggests a high level of redundancy in laboratory test repetition.