Your browser doesn't support javascript.
loading
Is Methionyl-tRNA Synthetase Applicable as a Diagnostic Marker for Lung Cancer in Bronchial Ultrasound-Guided Brushing Cells?
Lee, Kyungjong; Oh, Mijung; Lee, Kyo-Sun; Cha, Yoon Jin; Chang, Yoon Soo.
Affiliation
  • Lee K; Samsung Medical Center, Department of Medicine, Division of Pulmonary and Critical Care Medicine, Sungkyunkwan University School of Medicine, Seoul 06351, Korea.
  • Oh M; Medical Research Center, Sungkyunkwan University School of Medicine, Seoul 06351, Korea.
  • Lee KS; Department of Internal Medicine, Yonsei University College of Medicine, Seoul 06229, Korea.
  • Cha YJ; Department of Pathology, Yonsei University College of Medicine, Seoul 06229, Korea.
  • Chang YS; Department of Internal Medicine, Yonsei University College of Medicine, Seoul 06229, Korea.
Diagnostics (Basel) ; 11(10)2021 Oct 03.
Article in En | MEDLINE | ID: mdl-34679529
BACKGROUND AND OBJECTIVE: Methionyl-tRNA synthetase (MARS) and A variant of Aminoacyl-tRNA synthetase interacting multifunctional protein 2 (AIMP2) with an exon 2 deletion (AIMP2-DX2) are known to be overexpressed in lung cancer. However, their role as diagnostic markers in lung cancer has not been well established. Thus, we evaluated their diagnostic performance in brushed cells obtained from nodular lung lesions suspected of lung cancer. METHODS: Samples obtained by radial endobronchial ultrasound-guided brushing were processed for cytological examination with Papanicolaou (Pap) staining. Then, double IF staining with MARS and AIMP2-DX2 antibodies was measured in the cytology samples for peripheral lung nodules. The diagnostic performance was compared against biomarkers. RESULTS: MARS IF staining was the only independent staining method used for the prediction of malignant cells. The area under the curve (AUC) of conventional cytology, MARS IF, and MARS IF plus cytology was 0.64, 0.68, and 0.69, respectively. The diagnostic accuracy was increased in MARS IF plus conventional cytology compared with cytology alone (71% vs. 47%). CONCLUSIONS: The combination of MARS staining with conventional cytology showed increases in the diagnostic accuracy for diagnosing lung nodules suspected of lung cancer on chest-computed tomography scans.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies / Prognostic_studies Language: En Journal: Diagnostics (Basel) Year: 2021 Document type: Article Country of publication: Switzerland

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies / Prognostic_studies Language: En Journal: Diagnostics (Basel) Year: 2021 Document type: Article Country of publication: Switzerland