Your browser doesn't support javascript.
loading
The study of distance changes between lumbar bi-cortical pedicle screws and anterior large vessels in patients with lumbar spondylolisthesis.
Zhao, Li; Wan, Chenguang; Han, Shuhong; Li, Baofeng; Zheng, Shaoyi.
Affiliation
  • Zhao L; Department of Cardiovascular surgery, Nanfang Hospital of Southern Medical University, Guangzhou, 510000, Guangdong, China.
  • Wan C; Department of Neurosurgery, Tianjin First Central Hospital, Tianjin, 300000, China.
  • Han S; Department of Spine Surgery, Affiliated Hospital of Chengde Medical College, Chengde, 067000, Hebei, China.
  • Li B; Department of Orthopedics, General Hospital of Southern Theater Command of PLA, The first School of Clinical Medicine, Southern Medical University, Guangzhou, 510000, China. niren79817@163.com.
  • Zheng S; Department of Cardiovascular surgery, Nanfang Hospital of Southern Medical University, Guangzhou, 510000, Guangdong, China. zhsy@smu.edu.cn.
BMC Musculoskelet Disord ; 22(1): 920, 2021 Nov 01.
Article in En | MEDLINE | ID: mdl-34724945
ABSTRACT

OBJECTIVE:

This paper was a anatomical radiographic study of distance between lumbar bi-cortical pedicle screws (BPSs) and anterior large vessels (ALVs) in patients with lumbar spondylolisthesis, and to provide clinical basis for evaluating the safety of bi-cortical pedicle screw implantation during lumbar spondylolisthesis.

METHODS:

Complete Computed tomography (CT) data of 104 patients with grade I lumbar spondylolisthesis (L4 52 and L5 52) and 107 non-spondylolisthesis patients (control group) were collected in this study. The distances between lumbar 4,5(L4,5) and sacrum 1(S1) BPSs and ALVs (abdominal aorta, inferior vena cava, left and right common iliac artery, internal and external iliac artery) were respectively measured at different transverse screw angles (TSAs) (L45°,10°; L510°,15°; S10°,5°,10°) and analyzed by SPSS (v25.0). There were three types of distances from the anterior vertebral cortex (AVC) to the ALVs (DAVC-ALV) DAVC-ALV N, DAVC-ALV ≥ 0.50 cm, and DAVC-ALV < 0.50 cm; these different distances represented non-contact, distant and close ALV respectively.

RESULTS:

We calculated the incidences of screw tip contacting large vessels at different TSAs and provided the appropriate angle of screw implantation. In non-spondylolisthesis group, in L4, the appropriate left TSA was 5°, and the incidence of the close ALV was 4.62%. In S1, the appropriate left TSA was 0° and the incidence of the close ALV was 22.4%, while the appropriate right TSA was 10° and the incidence of the close ALV was 17.8%. In L4 spondylolisthesis group, in L4, the appropriate left TSA was 5°, and the incidence of the close ALV was 3.8%. In L5 spondylolisthesis group, in S1, the appropriate left TSA was 0° and the incidence of the close ALV was 19.2%, while the appropriate right TSA was 10° and the incidence of the close ALV was 21.2%. The use of BPS was not appropriate on the right side of L4 or on the either side of L5 both in spondylolisthesis and control group. In patients with lumbar 4 spondylolisthesis, the incidences of screw tip contacting large vessels were less than the control group in both L4 and 5. In patients with lumbar 5 spondylolisthesis, the incidences of screw tip contacting large vessels were less than the control group in L5, while there were no significant difference in S1.

CONCLUSION:

It is very important that considering the anatomical relationship between the AVC and the ALVs while planning BPSs. The use of BPS does not apply to every lumbar vertebra. In patients with lumbar spondylolisthesis and non-spondylolisthesis patients, the incidences of screw tip contacting large vessels are different.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Spinal Fusion / Spondylolisthesis / Pedicle Screws Limits: Humans Language: En Journal: BMC Musculoskelet Disord Journal subject: FISIOLOGIA / ORTOPEDIA Year: 2021 Document type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Spinal Fusion / Spondylolisthesis / Pedicle Screws Limits: Humans Language: En Journal: BMC Musculoskelet Disord Journal subject: FISIOLOGIA / ORTOPEDIA Year: 2021 Document type: Article Affiliation country: China