Your browser doesn't support javascript.
loading
Relative Source Power: A novel method for localizing epileptiform EEG discharges.
Scherg, Michael; Schulz, Reinhard; Berg, Patrick; Cho, Jae-Hyun; Bornfleth, Harald; Kural, Mustafa A; Woermann, Friedrich G; Bien, Christian G; Beniczky, Sándor.
Affiliation
  • Scherg M; BESA GmbH, Gräfelfing, Germany. Electronic address: mscherg@besa.de.
  • Schulz R; Department of Epileptology (Krankenhaus Mara), Bielefeld University, Medical School, Bielefeld, Germany.
  • Berg P; BESA GmbH, Gräfelfing, Germany.
  • Cho JH; BESA GmbH, Gräfelfing, Germany.
  • Bornfleth H; BESA GmbH, Gräfelfing, Germany.
  • Kural MA; Department of Clinical Neurophysiology, Aarhus University Hospital, Aarhus, Denmark.
  • Woermann FG; Department of Epileptology (Krankenhaus Mara), Bielefeld University, Medical School, Bielefeld, Germany.
  • Bien CG; Department of Epileptology (Krankenhaus Mara), Bielefeld University, Medical School, Bielefeld, Germany.
  • Beniczky S; Department of Clinical Neurophysiology, Aarhus University Hospital, Aarhus, Denmark; Department of Clinical Neurophysiology, Danish Epilepsy Centre, Dianalund, Denmark.
Clin Neurophysiol ; 133: 9-19, 2022 01.
Article in En | MEDLINE | ID: mdl-34788717
ABSTRACT

OBJECTIVE:

To validate relative source power (RSP) imaging of extratemporal interictal epileptiform discharges (IEDs).

METHODS:

The accuracy of RSP was validated in a cohort of patients with extratemporal focal epilepsy and a confined epileptogenic lesion (<19 cm3) using distance to the lesion, concordance with resected area and postoperative outcome. Performance was compared with three conventional

methods:

voltage maps, equivalent current dipole and a distributed source model.

RESULTS:

Thirty-three of 41 consecutive patients (80%) had IED averages suitable for analysis. While the peak negativity in voltage maps localized above the epileptogenic lesion only in 18 cases, RSP-maps matched in 29 cases (88%, p < 0.0026). Source localization showed a median distance of 9.8 mm from the lesion. Source-regions with 20 mm radius included 98% of all source-to-lesion distances. In the 21 surgical cases, outcome showed a sensitivity of 82.35% and specificity of 50% without significant differences between the three source imaging methods.

CONCLUSIONS:

RSP-maps provide a rapid, intuitive and more accurate source estimation than voltage maps. At sublobar level, RSP localizes with an accuracy similar to conventional methods and results of previous studies.

SIGNIFICANCE:

The definition of a source region with 20 mm radius helps in guiding further exploration in extratemporal focal epilepsy.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Brain / Epilepsy Limits: Adolescent / Adult / Female / Humans / Male / Middle aged Language: En Journal: Clin Neurophysiol Journal subject: NEUROLOGIA / PSICOFISIOLOGIA Year: 2022 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Brain / Epilepsy Limits: Adolescent / Adult / Female / Humans / Male / Middle aged Language: En Journal: Clin Neurophysiol Journal subject: NEUROLOGIA / PSICOFISIOLOGIA Year: 2022 Document type: Article