Development of Cd (II) Ion Probe Based on Novel Polyaniline-Multiwalled Carbon Nanotube-3-aminopropyltriethoxylsilane Composite.
Alruwais, Raja S; Adeosun, Waheed A; Alsafrani, Amjad E; Marwani, Hadi M; Asiri, Abdullah M; Khan, Imran; Jawaid, Mohammad; Khan, Anish.
Affiliation
  • Alruwais RS; Chemistry Department, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia.
  • Adeosun WA; Department of Chemistry, Faculty of Science and Humanities, Shaqra University, Dawadmi 11911, Saudi Arabia.
  • Alsafrani AE; Chemistry Department, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia.
  • Marwani HM; Center of Excellence for Advanced Materials Research, King Abdulaziz University, Jeddah 21589, Saudi Arabia.
  • Asiri AM; Chemistry Department, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia.
  • Khan I; Department of Chemistry, College of Science, University of Jeddah, Jeddah 21589, Saudi Arabia.
  • Jawaid M; Chemistry Department, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia.
  • Khan A; Center of Excellence for Advanced Materials Research, King Abdulaziz University, Jeddah 21589, Saudi Arabia.
Membranes (Basel) ; 11(11)2021 Nov 04.
Article in En | MEDLINE | ID: mdl-34832082
ABSTRACT
Cadmium belongs to the group of potentially toxic metals that have high health and environmental significance. Due to its adverse effects on the environment, this study develops an effective electrochemical sensor for detecting a polyaniline-multiwalled carbon nanotube-3-aminopropyltriethoxysilane (PANI-MWCNT-APTES) substrate cast on the GCE. The as-prepared PANI-MWCNT-APTES was prepared by a wet chemical method, and its formation was investigated using several techniques. As a result, the prepared material exhibited a limit of detection of 0.015 µM for cadmium ions (Cd2+) in the linear dynamic range of 0.05 µM to 50 µM. Furthermore, the PANI-MWCNT-APTES-modified GCE current response was stable, repeatable, reproducible, and short. In addition, PANI-MWCNT-APTES/GCE was harnessed for the first time for cadmium detection in real water samples, and the result was satisfactory. Therefore, the recorded results suggest that the newly designed PANI-MWCNT-APTES is a promising material for detecting Cd in the near future for human health and environmental protection.