Your browser doesn't support javascript.
loading
Dual-energy CT hybridation and kernel processing effects on the estimation of bone mineral mass and density: a calcination study on ex vivo human femur.
Wagner, Philippe Paul; Roux, Jean-Paul; Chuzel, Quentin; Szulc, Pawel; Bermond, François; Duboeuf, François; Chapurlat, Roland; Follet, Hélène; Pialat, Jean-Baptiste.
Affiliation
  • Wagner PP; Univ Lyon, Université Claude Bernard Lyon 1, INSERM, LYOS UMR1033, 69008, Lyon, France.
  • Roux JP; Univ Lyon, Université Claude Bernard Lyon 1, INSERM, LYOS UMR1033, 69008, Lyon, France.
  • Chuzel Q; Department of Radiology, Hospices Civils de Lyon, Hôpital Edouard Herriot, 69437, Lyon, France.
  • Szulc P; Univ Lyon, Université Claude Bernard Lyon 1, INSERM, LYOS UMR1033, 69008, Lyon, France.
  • Bermond F; Univ Lyon, Université Claude Bernard Lyon 1, Univ Gustave Eiffel, LBMC UMR_T 9406, Lyon, France.
  • Duboeuf F; Univ Lyon, Université Claude Bernard Lyon 1, INSERM, LYOS UMR1033, 69008, Lyon, France.
  • Chapurlat R; Univ Lyon, Université Claude Bernard Lyon 1, INSERM, LYOS UMR1033, 69008, Lyon, France.
  • Follet H; Department of Rheumatology, Hospices Civils de Lyon, Hôpital Edouard Herriot, 69437, Lyon, France.
  • Pialat JB; Univ Lyon, Université Claude Bernard Lyon 1, INSERM, LYOS UMR1033, 69008, Lyon, France.
Osteoporos Int ; 33(4): 909-920, 2022 Apr.
Article in En | MEDLINE | ID: mdl-34837503
ABSTRACT

INTRODUCTION:

Recent technological advances with dual-energy quantitative computed tomography (DEQCT) allow to combine two images of different level of energy to obtain simulated mono-energetic images at 60 keV (SIM60KeV-QCT) with improved image contrast in clinical practice. This study includes three topics (1) compare bone mineral content (BMC), areal and volumetric bone mineral density (aBMD, vBMD) obtained with SIM60KeV-QCT, single-energy QCT (SEQCT), and dual X-ray absorptiometry (DXA); (2) compare ash density and weight with respective vBMD and BMC assessed on SIM60KeV-QCT, SEQCT, and DXA; and (3) compare the influence of reconstruction kernels on the accuracy of vBMD and BMC using ash density and ash weight as the reference values.

METHODS:

DXA, SEQCT, and DEQCT acquisitions were performed ex vivo on 42 human femurs. Standard kernel (SK) and bone kernel (BK) were applied to each stack of images. Ten diaphyses and 10 femoral necks were cut, scanned, and reconstructed using the techniques described above. Finally, the bone specimens were calcined to obtain the ash weight.

RESULTS:

QCT analysis (SEQCT, SIM60KeV-QCT) underestimated BMC value compared to DXA. For femoral necks, all QCT analyses provided an unbiased estimate of ash weight but underestimated ash density regardless of the kernel used. For femoral diaphysis, SEQCT BK, SIM60KeV-QCT BK, and SK underestimated ash weight but not ash density.

CONCLUSION:

BMC and vBMD quantifications with the SIM60KeV-QCT gave similar results as the SEQCT. Further studies are needed to optimize the use of SIM60KeV-QCT in clinical situations. SK should be used given the effect of kernels on QCT assessment.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Bone Density / Femur Limits: Humans Language: En Journal: Osteoporos Int Journal subject: METABOLISMO / ORTOPEDIA Year: 2022 Document type: Article Affiliation country: France

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Bone Density / Femur Limits: Humans Language: En Journal: Osteoporos Int Journal subject: METABOLISMO / ORTOPEDIA Year: 2022 Document type: Article Affiliation country: France