Your browser doesn't support javascript.
loading
An automated mass spectrometric blood test for therapeutic drug monitoring of infliximab.
van der Gugten, J Grace; Bressler, Brian; DeMarco, Mari L.
Affiliation
  • van der Gugten JG; Department of Pathology and Laboratory Medicine, St. Paul's Hospital, Providence Health Care, Vancouver, Canada.
  • Bressler B; Department of Medicine, Division of Gastroenterology, St. Paul's Hospital, University of British Columbia, Vancouver, Canada.
  • DeMarco ML; Department of Pathology and Laboratory Medicine, St. Paul's Hospital, Providence Health Care, Vancouver, Canada.
Clin Mass Spectrom ; 12: 16-22, 2019 Apr.
Article in En | MEDLINE | ID: mdl-34841075
Infliximab is a monoclonal antibody therapy used to treat several chronic immune-mediated diseases, including Crohn's disease, ulcerative colitis, and rheumatoid arthritis. Infliximab acts by binding to tumor necrosis factor and, thus, inhibiting the inflammatory cascade. While it is a highly effective therapy, a subset of patients on infliximab will develop a loss of response to therapy. In these circumstances, therapeutic drug monitoring of infliximab offers a rational approach to clinical decision making and is associated with improved outcomes. While infliximab has most commonly been measured by immunometric approaches, mass spectrometric approaches offer the opportunity to improve test accuracy and reduce test costs. Herein, we describe a simple, bottom-up high performance liquid chromatography tandem mass spectrometry (LC-MS/MS) approach for quantitation of infliximab in serum. Method development included pre-digestion and digestion experiments to determine critical sample preparation steps, optimization of the workflow and selection of rapidly produced proteolytic peptide(s) for quantitation. The workflow was further improved by automating all sample preparation steps on a robotic liquid handler, facilitating implementation in routine clinical use. A method comparison was performed against a Health Canada and US Food and Drug Administration licensed enzyme-linked immunosorbent assay. Our LC-MS/MS assay accurately reported concentrations based on drug manufacturer targets and demonstrated no interference from endogenous antibodies to infliximab; immunoassay methods did not share these performance characteristics. This LC-MS/MS method provides a workflow amenable to implementation in a clinical laboratory and desired performance characteristics for guiding clinical decision making.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Prognostic_studies Language: En Journal: Clin Mass Spectrom Year: 2019 Document type: Article Affiliation country: Canada Country of publication: Netherlands

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Prognostic_studies Language: En Journal: Clin Mass Spectrom Year: 2019 Document type: Article Affiliation country: Canada Country of publication: Netherlands