Your browser doesn't support javascript.
loading
Novel Mg-0.5Ca-xMn Biodegradable Alloys Intended for Orthopedic Application: An In Vitro and In Vivo Study.
Munteanu, Corneliu; Vlad, Daniela Maria; Sindilar, Eusebiu-Viorel; Istrate, Bogdan; Butnaru, Maria; Pasca, Sorin Aurelian; Nastasa, Roxana Oana; Mihai, Iuliana; Burlea, Stefan-Lucian.
Affiliation
  • Munteanu C; Mechanical Engineering Department, "Gheorghe Asachi" Technical University of Iasi, 700050 Iasi, Romania.
  • Vlad DM; Technical Sciences Academy of Romania, 26 Dacia Blvd., 030167 Bucharest, Romania.
  • Sindilar EV; Faculty of Medical Bioengineering, "Grigore T. Popa" University of Medicine and Pharmacy from Iasi, 9-13 Kogalniceanu Str, 700454 Iasi, Romania.
  • Istrate B; TRANSCEND Research Centre, Regional Institute of Oncology, Str. G-ral Henri Mathias Berthelot 2-4, 700483 Iasi, Romania.
  • Butnaru M; Faculty of Veterinary Medicine, "Ion Ionescu de la Brad" Iasi University of Life Sciences, 8, Mihail Sadoveanu Alley, 700490 Iasi, Romania.
  • Pasca SA; Mechanical Engineering Department, "Gheorghe Asachi" Technical University of Iasi, 700050 Iasi, Romania.
  • Nastasa RO; Faculty of Medical Bioengineering, "Grigore T. Popa" University of Medicine and Pharmacy from Iasi, 9-13 Kogalniceanu Str, 700454 Iasi, Romania.
  • Mihai I; Faculty of Veterinary Medicine, "Ion Ionescu de la Brad" Iasi University of Life Sciences, 8, Mihail Sadoveanu Alley, 700490 Iasi, Romania.
  • Burlea SL; Mechanical Engineering Department, "Gheorghe Asachi" Technical University of Iasi, 700050 Iasi, Romania.
Materials (Basel) ; 14(23)2021 Nov 27.
Article in En | MEDLINE | ID: mdl-34885417
ABSTRACT
Mg-based biodegradable materials, used for medical applications, have been extensively studied in the past decades. The in vitro cytocompatibility study showed that the proliferation and viability (as assessed by quantitative MTT-assay-3-(4,5-dimethyltiazol-2-yl)-2,5-diphenyl tetrazolium bromide) were not negatively affected with time by the addition of Mn as an alloying element. In this sense, it should be put forward that the studied alloys don't have a cytotoxic effect according to the standard ISO 10993-5, i.e., the level of the cells' viability (cultured with the studied experimental alloys) attained both after 1 day and 5 days was over 82% (i.e., 82, 43-89, 65%). Furthermore, the fibroblastic cells showed variable morphology (evidenced by fluorescence microscopy) related to the alloy sample's proximity (i.e., related to the variation on the Ca, Mg, and Mn ionic concentration as a result of alloy degradation). It should be mentioned that the cells presented a polygonal morphology with large cytoplasmic processes in the vicinity of the alloy's samples, and a bipolar morphology in the remote region of the wells. Moreover, the in vitro results seem to indicate that only 0.5% Mn is sufficient to improve the chemical stability, and thus the cytocompatibility; from this point of view, it could provide some flexibility in choosing the right alloy for a specific medical application, depending on the specific parameters of each alloy, such as its mechanical properties and corrosion resistance. In order to assess the in vivo compatibility of each concentration of alloy, the pieces were implanted in four rats, in two distinct body regions, i.e., the lumbar and thigh. The body's reaction was followed over time, 60 days, both by general clinical examinations considering macroscopic changes, and by laboratory examinations, which revealed macroscopic and microscopic changes using X-rays, CT(Computed Tomography), histology exams and SEM (Scanning Electron Microscopy). In both anatomical regions, for each of the tested alloys, deformations were observed, i.e., a local reaction of different intensities, starting the day after surgery. The release of hydrogen gas that forms during Mg alloy degradation occurred immediately after implantation in all five of the groups examined, which did not affect the normal functionality of the tissues surrounding the implants. Imaging examinations (radiological and CT) revealed the presence of the alloy and the volume of hydrogen gas in the lumbar and femoral region in varying amounts. The biodegradable alloys in the Mg-Ca-Mn system have great potential to be used in orthopedic applications.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Materials (Basel) Year: 2021 Document type: Article Affiliation country: Romania

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Materials (Basel) Year: 2021 Document type: Article Affiliation country: Romania
...