Your browser doesn't support javascript.
loading
Electrochemically activated pencil lead electrode as a sensitive voltammetric sensor to determine gallic acid.
Alipour, Esmaeel; Mirzae Bolali, Fatemeh; Norouzi, Sheida; Saadatirad, Afsaneh.
Affiliation
  • Alipour E; Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran. Electronic address: i-alipour@tabrizu.ac.ir.
  • Mirzae Bolali F; Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran.
  • Norouzi S; Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran.
  • Saadatirad A; Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran.
Food Chem ; 375: 131871, 2022 May 01.
Article in En | MEDLINE | ID: mdl-34953243
ABSTRACT
An electrochemical sensor for the determination of some polyphenolic compounds such as Gallic acid (GA) and Galloyl esters was developed using the activated pencil lead electrode (APLE). At first, a study has been made of the optimum conditions for electrochemical activation of the pencil lead electrode. Potentiodynamic and potentiostatic strategies were investigated for activation of the pencil lead electrode and the results show that the potentiodynamic pretreatment gives better performance toward measurement of the polyphenolic compounds. Electrochemical properties of GA were investigated using chronoamperometry and cyclic voltammetry; and some thermodynamic and kinetic variables such as α, n α, and D were calculated. Sensitive differential pulse voltammetry (DPV) technique was applied for the determination of Gallic acid and Galloyl esters in different samples. Enhanced oxidation peak currents of Gallic acid were observed at APLE when compared with non-activated PLE. The calibration graph has two linear ranges of 0.49-24.3 µM and 0.07-0.83 mM, and the obtained limit of detection for S/N = 3 was 0.25 µM. Adsorptive stripping differential pulse voltammetry (AdSDPV) was also conducted to determine Gallic acid and Galloyl esters in sub-micromolar concentration range. Using the AdSDPV method, the limit of detection was improved and calculated to be 5.2 nM. The proposed method was successfully applied for quantification of the total concentration of Gallic acid and Galloyl esters in a variety of real samples such as black and green tea, and mango juice samples, and desirable recovery values indicated the good accuracy of the developed sensor.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Electrochemical Techniques / Gallic Acid Type of study: Diagnostic_studies Language: En Journal: Food Chem Year: 2022 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Electrochemical Techniques / Gallic Acid Type of study: Diagnostic_studies Language: En Journal: Food Chem Year: 2022 Document type: Article