Your browser doesn't support javascript.
loading
Analysis of sodium 2-mercaptoethane sulfonate in rat plasma using high performance liquid chromatography tandem-mass spectrometry.
Donkor, Abigail B; White, Carl W; Nick, Heidi J; Logue, Brian A.
Affiliation
  • Donkor AB; Department of Chemistry and Biochemistry, South Dakota State University, Box 2202, Brookings, South Dakota 57007, USA.
  • White CW; Department of Pediatrics-Pulmonary and Sleep Medicine Section, University of Colorado Anschutz Medical Campus, Aurora, CO, 80045, USA.
  • Nick HJ; Department of Pediatrics-Pulmonary and Sleep Medicine Section, University of Colorado Anschutz Medical Campus, Aurora, CO, 80045, USA.
  • Logue BA; Department of Chemistry and Biochemistry, South Dakota State University, Box 2202, Brookings, South Dakota 57007, USA. Electronic address: brian.logue@sdstate.edu.
Article in En | MEDLINE | ID: mdl-34974317
ABSTRACT
Sodium 2-mercaptoethane sulfonate (MESNA) is a thiol-containing compound that has proven to be effective in inactivating acrolein, the toxic metabolite of some anti-cancer drugs (e.g., cyclophosphamide and ifosphamide). Also, it scavenges free radicals which cause numerous disorders by attacking biological molecules. Current methods available to analyze MESNA in biological matrices include colorimetry and high-performance liquid chromatography (HPLC) with ultraviolet, fluorescence, or electrochemical detection. These methods have several limitations including low sensitivity, poor selectivity, a high degree of difficulty, and long analysis times. Hence, a rapid, simple, and sensitive HPLC tandem mass spectrometry (MS/MS) method was developed and validated to quantify MESNA in rat plasma following IP administration. The analysis of MESNA was accomplished via plasma protein precipitation, centrifugation, supernatant evaporation, reconstitution, and HPLC-MS/MS analysis. The method showcases an outstanding limit of detection (20 nM), excellent linearity (R2 = 0.999, and percent residual accuracy >90%) and a wide linear range (0.05-200 µM). The method also produced good accuracy and precision (100 ± 10% and <10% relative standard deviation, respectively). The validated method was successfully used to analyze MESNA from treated animals and will allow easier development of MESNA for therapeutic purposes.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Chromatography, High Pressure Liquid / Mesna / Tandem Mass Spectrometry Type of study: Prognostic_studies Limits: Animals Language: En Journal: J Chromatogr B Analyt Technol Biomed Life Sci Journal subject: ENGENHARIA BIOMEDICA Year: 2022 Document type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Chromatography, High Pressure Liquid / Mesna / Tandem Mass Spectrometry Type of study: Prognostic_studies Limits: Animals Language: En Journal: J Chromatogr B Analyt Technol Biomed Life Sci Journal subject: ENGENHARIA BIOMEDICA Year: 2022 Document type: Article Affiliation country: United States