Your browser doesn't support javascript.
loading
NMMD: Efficient Cryo-EM Flexible Fitting Based on Simultaneous Normal Mode and Molecular Dynamics atomic displacements.
Vuillemot, Rémi; Miyashita, Osamu; Tama, Florence; Rouiller, Isabelle; Jonic, Slavica.
Affiliation
  • Vuillemot R; IMPMC - UMR 7590 CNRS, Sorbonne Université, Muséum National d'Histoire Naturelle, Paris, France; Department of Biochemistry & Pharmacology and Bio21 Molecular Science and Biotechnology Institute, University of Melbourne, Victoria, Australia. Electronic address: https://twitter.com/@RemiVuillemot
  • Miyashita O; RIKEN Center for Computational Science, Japan.
  • Tama F; Department of Physics, Graduate School of Science and Institute of Transformative Bio-Molecules, Nagoya University, Japan. Electronic address: https://twitter.com/@Florence_Tama.
  • Rouiller I; Department of Biochemistry & Pharmacology and Bio21 Molecular Science and Biotechnology Institute, University of Melbourne, Victoria, Australia. Electronic address: https://twitter.com/@IsabellRouill5.
  • Jonic S; IMPMC - UMR 7590 CNRS, Sorbonne Université, Muséum National d'Histoire Naturelle, Paris, France. Electronic address: slavica.jonic@upmc.fr.
J Mol Biol ; 434(7): 167483, 2022 04 15.
Article in En | MEDLINE | ID: mdl-35150654
ABSTRACT
Atomic models of cryo electron microscopy (cryo-EM) maps of biomolecular conformations are often obtained by flexible fitting of the maps with available atomic structures of other conformations (e.g., obtained by X-ray crystallography). This article presents a new flexible fitting method, NMMD, which combines normal mode analysis (NMA) and molecular dynamics simulation (MD). Given an atomic structure and a cryo-EM map to fit, NMMD simultaneously estimates global atomic displacements based on NMA and local displacements based on MD. NMMD was implemented by modifying EMfit, a flexible fitting method using MD only, in GENESIS 1.4. As EMfit, NMMD can be run with replica exchange umbrella sampling procedure. The new method was tested using a variety of EM maps (synthetic and experimental, with different noise levels and resolutions). The results of the tests show that adding normal modes to MD-based fitting makes the fitting faster (40% in average) and, in the majority of cases, more accurate.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Molecular Dynamics Simulation Language: En Journal: J Mol Biol Year: 2022 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Molecular Dynamics Simulation Language: En Journal: J Mol Biol Year: 2022 Document type: Article
...