Your browser doesn't support javascript.
loading
Improved Performance in Measurement of Serum Cystatin C by Laboratories Participating in the College of American Pathologists 2019 CYS Survey.
Karger, Amy B; Long, Thomas; Inker, Lesley A; Eckfeldt, John H.
Affiliation
  • Karger AB; From the Department of Laboratory Medicine & Pathology, University of Minnesota, Minneapolis (Karger, Eckfeldt).
  • Long T; From the Department of Biostatistics, College of American Pathologists, Northfield, Illinois (Long).
  • Inker LA; From William B. Schwartz Division of Nephrology, Tufts Medical Center, Department of Medicine, Tufts University School of Medicine, Boston, Massachusetts (Inker).
  • Eckfeldt JH; From the Department of Laboratory Medicine & Pathology, University of Minnesota, Minneapolis (Karger, Eckfeldt).
Arch Pathol Lab Med ; 146(10): 1218-1223, 2022 10 01.
Article in En | MEDLINE | ID: mdl-35192685
ABSTRACT
CONTEXT.­ Use of cystatin C for glomerular filtration rate estimation (eGFR) has garnered heightened interest as a means to avoid race-based medicine, since eGFRcys equations do not require specification of race. Before considering more widespread use of cystatin C, it is important to confirm that assays provide accurate measurements of cystatin C concentration, to ensure accurate GFR estimates. OBJECTIVE.­ To determine if the accuracy of cystatin C measurements in laboratories participating in the College of American Pathologists (CAP) Cystatin C (CYS) survey has improved since 2014. DESIGN.­ Two fresh frozen serum pools, the first from healthy donors without chronic kidney disease (CKD), and the second from patients with CKD, along with a synthetically prepared elevated cystatin C pool, were sent to laboratories participating in the 2019 CYS-A survey. Target values were established by using 2 immunoassays and a bracketed 2-point calibration with diluted ERM-DA471/IFCC reference material. RESULTS.­ For the healthy donor fresh frozen pool (ERM-DA471/IFCC-traceable target of 0.725 mg/L), the all-method mean (standard deviation, coefficient of variation) was 0.731 mg/L (0.071, 9.7%). For the CKD pool (ERM-DA471/IFCC-traceable target of 2.136 mg/L), the all-method mean was 2.155 mg/L (0.182, 8.4%). For the synthetically spiked pool (ERM-DA471/IFCC-traceable target of 1.843 mg/L), the all-method mean was 1.886 mg/L (0.152, 8.1%). This represents marked improvement in accuracy and between-method agreement compared to the 2014 CAP survey. CONCLUSIONS.­ Manufacturers have markedly improved accuracy and between-method agreement of cystatin C measurement procedures since 2014, which allows for greater confidence in estimated GFR relying on cystatin C.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Renal Insufficiency, Chronic / Cystatin C Type of study: Diagnostic_studies Limits: Humans Language: En Journal: Arch Pathol Lab Med Year: 2022 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Renal Insufficiency, Chronic / Cystatin C Type of study: Diagnostic_studies Limits: Humans Language: En Journal: Arch Pathol Lab Med Year: 2022 Document type: Article