Your browser doesn't support javascript.
loading
Low-frequency ultrasound-assisted esterification of Bixa orellana L. seed starch with octenyl succinic anhydride.
Silva, Eric Keven; Anthero, Ana Gabriela da S; Emerick, Lucas B; Zabot, Giovani L; Hubinger, Miriam D; Meireles, Maria Angela A.
Affiliation
  • Silva EK; School of Food Engineering, University of Campinas, Rua Monteiro Lobato, 80, 13083-862 Campinas, SP, Brazil. Electronic address: engerickeven@gmail.com.
  • Anthero AGDS; School of Food Engineering, University of Campinas, Rua Monteiro Lobato, 80, 13083-862 Campinas, SP, Brazil.
  • Emerick LB; School of Food Engineering, University of Campinas, Rua Monteiro Lobato, 80, 13083-862 Campinas, SP, Brazil.
  • Zabot GL; Laboratory of Agroindustrial Processes Engineering (LAPE), Federal University of Santa Maria (UFSM), Sete de Setembro St., 1040, Cachoeira do Sul, RS, 96508-010, Brazil.
  • Hubinger MD; School of Food Engineering, University of Campinas, Rua Monteiro Lobato, 80, 13083-862 Campinas, SP, Brazil.
  • Meireles MAA; School of Food Engineering, University of Campinas, Rua Monteiro Lobato, 80, 13083-862 Campinas, SP, Brazil.
Int J Biol Macromol ; 207: 1-8, 2022 May 15.
Article in En | MEDLINE | ID: mdl-35196570
ABSTRACT
This study aimed to evaluate the impact of the ultrasound intensity (0, 5, 10, and 20 W/cm2) on the esterification of annatto (Bixa orellana L.) seed starch with octenyl succinic anhydride (OSA) employing a short processing time (5 min) to produce a novel emulsifier. OSA-esterified annatto seed starches were examined according to their degree of substitution (DS), amylose content, granule size distribution, microstructure, and X-ray diffractogram. Also, the performance of the OSA-modified annatto seed starch to stabilize colloidal systems was compared to commercial samples of OSA-modified starches. For this, annatto seed oil-in-water emulsions were produced and characterized according to their droplet size distribution, microstructure, and kinetic stability. Increasing ultrasound intensity from 5 W/cm2 to 20 W/cm2, DS values reached up to 0.139 ± 0.031. Likewise, these treatments yielded approximately 1.24-1.36 times more amylose content than the sample without ultrasound application. Most of the starch granules presented smooth surfaces without visible fissures. The higher ultrasound intensity hindered the aggregation of starch granules, thus forming well-defined elliptical particles. On the other hand, the increase of the ultrasound intensity did not change Brouckere mean diameter of the starch granules. No significant qualitative differences were seen in the X-ray diffractograms in terms of diffraction angle and peak intensity, indicating that the main functional characteristics of starches were not altered with ultrasound treatment. Furthermore, modified annatto starch was able to stabilize annatto seed oil-in-water emulsions. When compared to two commercial modified starches, OSA-esterified annatto starch produced a colloidal system with a larger Sauter mean diameter (14 ± 2 µm). However, the emulsion stabilized with modified annatto starch was more kinetically stable during the storage time in comparison to those stabilized with commercial starches.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Succinic Anhydrides / Amylose Type of study: Qualitative_research Language: En Journal: Int J Biol Macromol Year: 2022 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Succinic Anhydrides / Amylose Type of study: Qualitative_research Language: En Journal: Int J Biol Macromol Year: 2022 Document type: Article