Your browser doesn't support javascript.
loading
Does robotic technology successfully restore the joint line after total knee arthroplasty? A retrospective analysis.
Agrawal, Varun O; Gadekar, Anup P; Vaidya, Narendra.
Affiliation
  • Agrawal VO; Joint Replacement and Trauma Department, Lokmanya Hospital, 484/6, Shiv Darshan Rd, Mitra Mandal Colony, Parvati Paytha, Pune, Maharashtra, 411009, India. agrawalovarun@gmail.com.
  • Gadekar AP; Department of Arthroplasty, Lokmanya Hospital, 484/6, Shiv Darshan Rd, Mitra Mandal Colony, Parvati Paytha, Pune, Maharashtra, 411009, India. agrawalovarun@gmail.com.
  • Vaidya N; Department of Arthroplasty, Lokmanya Hospital, 484/6, Shiv Darshan Rd, Mitra Mandal Colony, Parvati Paytha, Pune, Maharashtra, 411009, India.
Arthroplasty ; 4(1): 6, 2022 Jan 05.
Article in En | MEDLINE | ID: mdl-35236508
ABSTRACT

BACKGROUND:

Our study aims to determine the effectiveness of robotic technology for total knee arthroplasty in the successful restoration of the joint line of the knee with respect to that of a normal human anatomical knee. The restoration of the joint line is an important technical goal on which the postoperative outcomes and the success of the surgery depend.

METHODS:

Sixty-four postoperative plain anteroposterior radiographs of 60 patients, who received total knee arthroplasty by using the robotic technology were analyzed and compared with 66 similar radiographs of 60 patients who received the conventional method. The distances of the lateral epicondyle to the joint line (LEJL) and proximal tibiofibular joint to the joint line (PTFJJL) were calculated and analyzed.

RESULTS:

We found that the mean value of LEJL minus PTFJJL in the robotic group was 0.334 ± 0.115 (mean ± SD), while in the conventional group, it was 2.304 ± 0.308. The difference between the two groups was statistically significant. The mean ratio (LEJLPTFJJL) in the robotic group was also equal to 1.017 ± 0.042.

CONCLUSION:

From these findings it could be concluded that the robotic technology significantly increases the accuracy of the total knee arthroplasty and, compared to the conventional method, achieves an almost anatomical position of the joint line.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Arthroplasty Year: 2022 Document type: Article Affiliation country: India

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Arthroplasty Year: 2022 Document type: Article Affiliation country: India