Your browser doesn't support javascript.
loading
Conventional Total Thyroidectomy Using a Novel Single Retractor: Technical Note for Apollo®.
Pino, Antonella; Frattini, Francesco; Matarese, Alessandro; Villardita, Viola; Kim, Hoon Yub; Donatini, Gianluca; Wu, Che Wei; Chai, Young Jun; Dionigi, Gianlorenzo.
Affiliation
  • Pino A; Division of General Surgery, Endocrine Surgery Section, Istituto Auxologico Italiano IRCCS, Milan, Italy.
  • Frattini F; Department of Human Pathology in Adulthood and Childhood "G. Barresi", University Hospital G. Martino, University of Messina, Italy.
  • Matarese A; Division of General Surgery, ASST Settelaghi, Tradate, Varese, Italy.
  • Villardita V; Division of General Surgery, Endocrine Surgery Section, Istituto Auxologico Italiano IRCCS, Milan, Italy.
  • Kim HY; Department of Pathophysiology and Transplantation, University of Milan, Italy.
  • Donatini G; Division of General Surgery, Endocrine Surgery Section, Istituto Auxologico Italiano IRCCS, Milan, Italy.
  • Wu CW; Department of Pathophysiology and Transplantation, University of Milan, Italy.
  • Chai YJ; Department of Surgery, KUMC Thyroid Center, Korea University Hospital, Korea University College of Medicine, Seoul, Korea.
  • Dionigi G; Department of Visceral and Endocrine Surgery, CHU Poitiers-University of Poitiers, Poitiers, France.
Surg Technol Int ; 40: 114-117, 2022 May 19.
Article in En | MEDLINE | ID: mdl-35415832
ABSTRACT
Despite the increasingly innovative techniques developed in thyroid surgery to offer patients minimally invasive and scarless interventions, conventional open procedures still account for most of the interventions performed in this field. The surgical incision length has been significantly reduced, from 6-9 cm to 3 cm, and therefore patients perceive the scar to be highly acceptable. In this technical note, we present the use of a new single retractor (APOLLO®; AFS MEDICAL GmbH, Teesdorf, Austria) for conventional open thyroidectomies with intraoperative neuromonitoring. This device offers several advantages a) better exposure of the surgical field; b) less traction on skin flaps and neck muscles; and c) protection of the skin edges from the heat generated by energy-based devices/coagulating instruments, with consequent better healing.
Subject(s)
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Thyroid Gland / Thyroidectomy Limits: Humans Language: En Journal: Surg Technol Int Year: 2022 Document type: Article Affiliation country: Italy
Search on Google
Collection: 01-internacional Database: MEDLINE Main subject: Thyroid Gland / Thyroidectomy Limits: Humans Language: En Journal: Surg Technol Int Year: 2022 Document type: Article Affiliation country: Italy