Your browser doesn't support javascript.
loading
A simple and rapid approach for on-site analysis of nicotine in tobacco based on a screen-printed electrode as an electrochemical sensor.
Sha, Yunfei; Yu, Jie; Xiong, Junwei; Yu, Chaofan; Zhu, Xiaoyu; Zhang, Bingqian; Fei, Ting; Wu, Da.
Affiliation
  • Sha Y; Technical Center of Shanghai Tobacco Group Co., Ltd, Shanghai 201315, China. feit@sh.tobacco.com.cn.
  • Yu J; Technical Center of Shanghai Tobacco Group Co., Ltd, Shanghai 201315, China. feit@sh.tobacco.com.cn.
  • Xiong J; Technical Center of Shanghai Tobacco Group Co., Ltd, Shanghai 201315, China. feit@sh.tobacco.com.cn.
  • Yu C; Technical Center of Shanghai Tobacco Group Co., Ltd, Shanghai 201315, China. feit@sh.tobacco.com.cn.
  • Zhu X; College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China.
  • Zhang B; College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China.
  • Fei T; Technical Center of Shanghai Tobacco Group Co., Ltd, Shanghai 201315, China. feit@sh.tobacco.com.cn.
  • Wu D; Technical Center of Shanghai Tobacco Group Co., Ltd, Shanghai 201315, China. feit@sh.tobacco.com.cn.
Anal Methods ; 14(16): 1579-1584, 2022 04 21.
Article in En | MEDLINE | ID: mdl-35416201
ABSTRACT
In this study, we report a portable kit consisting of a portable workstation, gold screen-printed electrode (SPE), 0.45 µm filter membrane, phosphate buffer solution (PBS), and acetic acid (1%) for point-of-use (POU) analysis of nicotine in tobacco. The activated-screen-printed electrode (A-SPE) displayed superior electron transmission efficiency, and the A-SPE without modification was employed for high-performance analysis of nicotine in actual tobacco after simple sample pretreatment. Remarkably, the fabricated nicotine sensor exhibited a broad working range of 10-100 µg g-1, a low limit of detection (LOD) of 6.4 µg mL-1, good stability, selectivity, and practicality under the optimal conditions. The method was applied to the determination of nicotine in (spiked) samples. Satisfactory recovery results demonstrated that the as-prepared portable kit method with outstanding electrocatalysis ability was feasible for analysis of nicotine in tobacco. Moreover, the values obtained using the A-SPE were in good agreement with those determined by gas chromatography-flame ionization detection (GC-FID), which confirms the feasibility and validity of the present method. The results of the as-proposed portable kit provided a new strategy for analyzing nicotine in actual tobacco samples.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tobacco Products / Nicotine Language: En Journal: Anal Methods Year: 2022 Document type: Article Affiliation country: China

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tobacco Products / Nicotine Language: En Journal: Anal Methods Year: 2022 Document type: Article Affiliation country: China