This study aims to explore the clinical efficacy of arthroscopic-assisted reduction combined with robot-navigated nail placement in the treatment of talar neck fractures. The clinical data of 13 patients with talar neck fracture in Xuzhou Benevolent Hospital from January 2018 to January 2021 were analyzed in the retrospective study. Among them, there were 9 males and 4 females, aged (36±12) years; there were 8 cases suffered on the right and 5 cases on the left. All patients were reset under arthroscopy and cannulated screws were placed in combination with three-dimensional navigation and positioning of orthopedic robot. The wounds and complications were observed in the postoperative follow-up. The activities of bilateral ankle dorsiflexion and plantar flexion were measured in the last follow-up. The visual analogue scale score (VAS) of pain in the affected feet before operation were compared with that at the last follow-up. The ankle and hind foot work energy scale of American Foot and Ankle Association (AOFAS) was used to assess the ankle function. The results showed that the wounds of 13 patients healed in one stage. The operation time was (95±45) min and the blood lose was (45±10) ml. All the patients were followed-up for (15.0±3.5) months. Two cases developed subtalar arthritis without talus necrosis and fracture nonunion. At the last follow-up, there was no significant difference in the dorsal extension and plantar flexion of the ankle between the affected side and the healthy side (25.8°±1.9° vs 26.2°±2.3°, 44.2°±2.7° vs 44.7°±2.8°, both P>0.05). The VAS score of pain in the affected foot at the last follow-up was 0.53±0.18, it was significantly lower than that before operation (0.87±0.29) (P<0.001). The mean AOFAS ankle and hind foot energy scale of the ankle function was 93.5 at the last follow-up. It's showed that treatment of talus neck fracture with arthroscopy assisted and robot guided nail placement is satisfactory and is worthy of clinical promotion.
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Robotics
/
Talus
/
Ankle Fractures
Type of study:
Observational_studies
Limits:
Female
/
Humans
/
Male
Language:
Zh
Journal:
Zhonghua Yi Xue Za Zhi
Year:
2022
Document type:
Article
Affiliation country:
China
Country of publication:
China