Your browser doesn't support javascript.
loading
Porous Pd-Sn Alloy Nanotube-Based Chemiresistor for Highly Stable and Sensitive H2 Detection.
Song, Lu; Ahn, Jaewan; Kim, Dong-Ha; Shin, Hamin; Kim, Il-Doo.
Affiliation
  • Song L; Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.
  • Ahn J; Membrane Innovation Center for Anti-virus & Air-quality Control, KI Nanocentury, KAIST, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.
  • Kim DH; Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.
  • Shin H; Membrane Innovation Center for Anti-virus & Air-quality Control, KI Nanocentury, KAIST, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.
  • Kim ID; Department of Materials Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Republic of Korea.
ACS Appl Mater Interfaces ; 14(24): 28378-28388, 2022 Jun 22.
Article in En | MEDLINE | ID: mdl-35679507
ABSTRACT
While H2 is indispensable as a green fuel source, it is highly flammable and explosive. Because it is difficult to detect due to its lack of odor and color, a solution for proper monitoring of H2 leakage is essential to ensure safe handling. To this end, we have successfully fabricated hollow Pd-Sn alloy nanotubes (NTs) with a Brunauer-Emmett-Teller surface area of 223.0 m2/g through electrospinning and a subsequent etching method, which is the first demonstration of synthesizing Pd-based hollow alloy nanofibers with ultrafine grain sizes. We found that the alloying of Pd with Sn could effectively prevent degradation of the sensing performance upon the α-ß phase transition during hydrogen detection. Besides, the highly porous structure with smaller nanograins offered more exposed active sites and higher gas accessibility to bulk materials. The resultant Pd-Sn NTs exhibited excellent sensitivity toward H2 (0.00005-3%). Notably, the limit of detection of 0.0001% is an outstanding achievement on H2 sensing among state-of-the-art H2 sensors. Moreover, when exposed to a high concentration of H2 (3%), Pd-Sn NTs showed excellent cycling stability with a standard deviation of 0.07% and a sensitivity of 9.27%. These obtained sensing results indicate that Pd-Sn NTs can be used as a highly sensitive and stable H2 gas sensor at room temperature (25 °C).