Your browser doesn't support javascript.
loading
Ultrasound-guided repositioning technique for partially expelled intrauterine device: descriptive feasibility study.
Yamaguti, E M M; Sontag Dos Reis, E T; Martins, W P; Nadai, M N; Soares, N F; da Silva Costa, F; Vieira, C S.
Affiliation
  • Yamaguti EMM; Department of Gynecology and Obstetrics, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, Brazil.
  • Sontag Dos Reis ET; Department of Gynecology and Obstetrics, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, Brazil.
  • Martins WP; SEMEAR Fertilidade, Reproductive Medicine, Ribeirão Preto, Brazil.
  • Nadai MN; Department of Gynecology and Obstetrics, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, Brazil.
  • Soares NF; Department of Gynecology and Obstetrics, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, Brazil.
  • da Silva Costa F; Department of Gynecology and Obstetrics, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, Brazil.
  • Vieira CS; Maternal-Fetal Medicine Unit, Gold Coast University Hospital, Southport, Queensland, Australia.
Ultrasound Obstet Gynecol ; 61(1): 109-113, 2023 01.
Article in En | MEDLINE | ID: mdl-35793228
ABSTRACT

OBJECTIVE:

To describe the feasibility of an ultrasound-guided repositioning technique for partially expelled intrauterine devices (IUDs) without use of sedation.

METHODS:

This was a descriptive feasibility study of patients with a partially expelled IUD managed in our outpatient clinic from January 2016 to February 2020. The partially expelled IUDs (vertical arm extending partially or entirely through the cervical canal) were repositioned at the uterine fundus using Hartmann alligator forceps under ultrasound guidance. Paracervical or intracervical anesthesia and prophylactic antibiotics were not used. Data related to the procedure and 6-month follow-up were extracted from patient medical records. The primary outcome was the success rate of the repositioning procedure, defined as ultrasound confirmation of the entire IUD located above the internal os. Secondary outcomes included the retention and expulsion rates of the repositioned IUD at 6 months after the procedure and description of complications.

RESULTS:

We included data from 55 women with a partially expelled IUD (35 levonorgestrel IUDs and 20 copper IUDs) referred for repositioning. Ultrasound-guided repositioning of the IUD was successful in 51 (92.7%) cases, while the procedure was not completed in four patients due to pain. Of the 55 procedures, 48 (87.3%) were performed by obstetrics and gynecology trainees under the supervision of a senior specialist. Among the 51 successfully repositioned IUDs, nine (17.6%) were expelled within 6 months after the procedure and six patients were lost to follow-up. No uterine perforation or infection-related complications occurred within 6 months of the procedure.

CONCLUSION:

The ultrasound-guided repositioning technique appears to be a safe and feasible approach for partially expelled IUDs. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Intrauterine Devices Limits: Female / Humans / Pregnancy Language: En Journal: Ultrasound Obstet Gynecol Journal subject: DIAGNOSTICO POR IMAGEM / GINECOLOGIA / OBSTETRICIA Year: 2023 Document type: Article Affiliation country: Brazil

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Intrauterine Devices Limits: Female / Humans / Pregnancy Language: En Journal: Ultrasound Obstet Gynecol Journal subject: DIAGNOSTICO POR IMAGEM / GINECOLOGIA / OBSTETRICIA Year: 2023 Document type: Article Affiliation country: Brazil