Your browser doesn't support javascript.
loading
Ultrasound-Guided Umbilical Venous Catheter Insertion to Reduce Rate of Catheter Tip Malposition in Neonates: A Randomized, Controlled Trial.
Kaur, Amandeep; Manerkar, Swati; Patra, Saikat; Kalamdani, Pavan; Kalathingal, Thaslima; Mondkar, Jayashree.
Affiliation
  • Kaur A; Department of Neonatology, Lokmanya Tilak Municipal Medical College and General Hospital, Sion, Mumbai, Maharashtra, 400022, India.
  • Manerkar S; Department of Neonatology, Lokmanya Tilak Municipal Medical College and General Hospital, Sion, Mumbai, Maharashtra, 400022, India. drswatimanerkar@gmail.com.
  • Patra S; Department of Neonatology, Lokmanya Tilak Municipal Medical College and General Hospital, Sion, Mumbai, Maharashtra, 400022, India.
  • Kalamdani P; Department of Neonatology, Lokmanya Tilak Municipal Medical College and General Hospital, Sion, Mumbai, Maharashtra, 400022, India.
  • Kalathingal T; Department of Neonatology, Lokmanya Tilak Municipal Medical College and General Hospital, Sion, Mumbai, Maharashtra, 400022, India.
  • Mondkar J; Department of Neonatology, Lokmanya Tilak Municipal Medical College and General Hospital, Sion, Mumbai, Maharashtra, 400022, India.
Indian J Pediatr ; 89(11): 1093-1098, 2022 11.
Article in En | MEDLINE | ID: mdl-35881217
ABSTRACT

OBJECTIVE:

To investigate whether ultrasound-guided umbilical venous catheter (UVC) insertion (US group) reduced the rate of malpositioning of the catheter tip compared to the standard method of insertion (SD group).

METHODS:

In this open-label, randomized, controlled trial, neonates admitted to NICU within the first week of life were randomly assigned to the US group (n = 26) or SD group (n = 27). Neonates with major congenital anomalies of the thorax and abdomen were excluded. The primary outcome was the rate of malpositioning of the catheter tip.

RESULTS:

The rate of malpositioning of the catheter tip was observed in a significantly lower number of neonates in the US group as compared to the SD group (11/26, 42.3% vs. 20/27, 74%; RR = 0.57, 95% CI 0.34 to 0.94, p = 0.019). As more of the UVCs were positioned optimally in the first attempt in the US group than SD group, the need for repeated attempts at catheter repositioning was reduced, resulting in reduced procedure time (minutes) [mean (SD), 23.96 (6.42) vs. 30 (1.83); mean difference 6.04 (95% CI 3.46 to 8.62), p = 0.005]. This also led to a reduction in the additional X-ray exposure in the US group (n = 11) compared to the SD group (n = 20) [95% CI 3.12 to 44.26; p = 0.020].

CONCLUSION:

Ultrasound-guided UVC insertion significantly reduced the rate of catheter tip malposition. It also reduced the number of attempts at catheter manipulation, procedure time, and X-ray exposures. With adequate training, it could be incorporated into routine bedside practice during UVC insertion for optimum placement. TRIAL REGISTRATION Clinical Trial Registry of India ( www.ctri.nic.in ) CTRI/2021/03/031894.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Catheterization, Central Venous / Catheterization Type of study: Clinical_trials / Diagnostic_studies Limits: Humans / Newborn Language: En Journal: Indian J Pediatr Year: 2022 Document type: Article Affiliation country: India

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Catheterization, Central Venous / Catheterization Type of study: Clinical_trials / Diagnostic_studies Limits: Humans / Newborn Language: En Journal: Indian J Pediatr Year: 2022 Document type: Article Affiliation country: India