Your browser doesn't support javascript.
loading
Determination of the endogenous OATP1B biomarkers glycochenodeoxycholate-3-sulfate and chenodeoxycholate-24-glucuronide in human and mouse plasma by a validated UHPLC-MS/MS method.
Jin, Yan; Li, Yang; Eisenmann, Eric D; Figg, William D; Baker, Sharyn D; Sparreboom, Alex; Hu, Shuiying.
Affiliation
  • Jin Y; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
  • Li Y; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
  • Eisenmann ED; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
  • Figg WD; Clinical Pharmacology Program, Office of the Clinical Director, National Cancer Institute, Bethesda, MD, USA.
  • Baker SD; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
  • Sparreboom A; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA.
  • Hu S; Division of Pharmaceutics and Pharmacology, College of Pharmacy, The Ohio State University, Columbus, OH, USA; Division of Outcomes and Translational Sciences, College of Pharmacy, The Ohio State University, Columbus, OH, USA. Electronic address: hu.1333@osu.edu.
Article in En | MEDLINE | ID: mdl-36054985
ABSTRACT
Glycochenodeoxycholate-3-sulfate (GCDCA-S) and chenodeoxycholate-24-glucuronide (CDCA-24G) are bile acid metabolites that potentially serve as endogenous biomarkers for drug-drug interactions mediated by the hepatic uptake transporters OATP1B1 and OATP1B3. We developed and validated a novel UHPLC-MS/MS method for the quantitative determination of GCDCA-S and CDCA-24G in mouse and human plasma with a lower limit of quantitation of 0.5 ng/mL. Chromatographic separation was achieved on an Accucore aQ column (50 mm × 2.1 mm, dp = 2.6 µm) maintained at 20 °C and a gradient mobile phase comprising 2 mM ammonium acetate in water and methanol. The extraction recoveries of GCDCA-S and CDCA-24G were >80 %, and linear (r2 > 0.99) calibration curves ranged 0.5-100 ng/mL (CDCA-24G and GCDCA-S in mouse plasma) or 0.5-1000 ng/mL (GCDCA-S in mouse plasma). Values for precision (CV < 11.6 %) and accuracy bias (10.9 %) of analyte-spiked quality control samples verified that water was an acceptable matrix to prepare calibrators. This method was successfully applied to establish baseline activity of OATP1B1/OATP1B3 in humans and mice and establish the in vivo effects of OATP1B1/OATP1B3 inhibitors rifampin and micafungin.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Glucuronides / Tandem Mass Spectrometry Limits: Animals / Humans Language: En Journal: J Chromatogr B Analyt Technol Biomed Life Sci Journal subject: ENGENHARIA BIOMEDICA Year: 2022 Document type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Glucuronides / Tandem Mass Spectrometry Limits: Animals / Humans Language: En Journal: J Chromatogr B Analyt Technol Biomed Life Sci Journal subject: ENGENHARIA BIOMEDICA Year: 2022 Document type: Article Affiliation country: United States