Your browser doesn't support javascript.
loading
Drawn-on-Skin Sensors from Fully Biocompatible Inks toward High-Quality Electrophysiology.
Patel, Shubham; Ershad, Faheem; Lee, Jimmy; Chacon-Alberty, Lourdes; Wang, Yifan; Morales-Garza, Marco A; Haces-Garcia, Arturo; Jang, Seonmin; Gonzalez, Lei; Contreras, Luis; Agarwal, Aman; Rao, Zhoulyu; Liu, Grace; Efimov, Igor R; Zhang, Yu Shrike; Zhao, Min; Isseroff, Roslyn Rivkah; Karim, Alamgir; Elgalad, Abdelmotagaly; Zhu, Weihang; Wu, Xiaoyang; Yu, Cunjiang.
Affiliation
  • Patel S; Department of Mechanical Engineering, University of Houston, Houston, TX, 77204, USA.
  • Ershad F; Department of Biomedical Engineering, University of Houston, Houston, TX, 77204, USA.
  • Lee J; Ben May Department for Cancer Research, The University of Chicago, Chicago, IL, 60637, USA.
  • Chacon-Alberty L; Regenerative Medicine Research, Texas Heart Institute, Houston, TX, 77030, USA.
  • Wang Y; Department of Biomedical Engineering, University of Houston, Houston, TX, 77204, USA.
  • Morales-Garza MA; Cardiovascular Surgery Research, Texas Heart Institute, Houston, TX, 77030, USA.
  • Haces-Garcia A; Department of Electrical and Computer Engineering, University of Houston, Houston, TX, 77204, USA.
  • Jang S; Materials Science and Engineering Program, University of Houston, Houston, TX, 77204, USA.
  • Gonzalez L; Department of Biomedical Engineering, University of Houston, Houston, TX, 77204, USA.
  • Contreras L; Department of Biomedical Engineering, University of Houston, Houston, TX, 77204, USA.
  • Agarwal A; Department of Chemical and Biomolecular Engineering, University of Houston, Houston, TX, 77204, USA.
  • Rao Z; Materials Science and Engineering Program, University of Houston, Houston, TX, 77204, USA.
  • Liu G; Bellaire High School, Bellaire, TX, 77041, USA.
  • Efimov IR; Department of Biomedical Engineering, The George Washington University, Washington, DC, 20052, USA.
  • Zhang YS; Division of Engineering in Medicine, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Cambridge, MA, 02139, USA.
  • Zhao M; Department of Dermatology, University of California Davis, Sacramento, CA, 95816, USA.
  • Isseroff RR; Department of Dermatology, University of California Davis, Sacramento, CA, 95816, USA.
  • Karim A; Department of Chemical and Biomolecular Engineering, University of Houston, Houston, TX, 77204, USA.
  • Elgalad A; Cardiovascular Surgery Research, Texas Heart Institute, Houston, TX, 77030, USA.
  • Zhu W; Department of Mechanical Engineering, University of Houston, Houston, TX, 77204, USA.
  • Wu X; Department of Engineering Technology, University of Houston, Houston, TX, 77204, USA.
  • Yu C; Ben May Department for Cancer Research, The University of Chicago, Chicago, IL, 60637, USA.
Small ; 18(36): e2107099, 2022 09.
Article in En | MEDLINE | ID: mdl-36073141
ABSTRACT
The need to develop wearable devices for personal health monitoring, diagnostics, and therapy has inspired the production of innovative on-demand, customizable technologies. Several of these technologies enable printing of raw electronic materials directly onto biological organs and tissues. However, few of them have been thoroughly investigated for biocompatibility of the raw materials on the cellular, tissue, and organ levels or with different cell types. In addition, highly accurate multiday in vivo monitoring using such on-demand, in situ fabricated devices has yet to be done. Presented herein is the first fully biocompatible, on-skin fabricated electronics for multiple cell types and tissues that can capture electrophysiological signals with high fidelity. While also demonstrating improved mechanical and electrical properties, the drawn-on-skin ink retains its properties under various writing conditions, which minimizes the variation in electrical performance. Furthermore, the drawn-on-skin ink shows excellent biocompatibility with cardiomyocytes, neurons, mice skin tissue, and human skin. The high signal-to-noise ratios of the electrophysiological signals recorded with the DoS sensor over multiple days demonstrate its potential for personalized, long-term, and accurate electrophysiological health monitoring.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Wearable Electronic Devices / Ink Limits: Animals / Humans Language: En Journal: Small Journal subject: ENGENHARIA BIOMEDICA Year: 2022 Document type: Article Affiliation country: United States Publication country: ALEMANHA / ALEMANIA / DE / DEUSTCHLAND / GERMANY

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Wearable Electronic Devices / Ink Limits: Animals / Humans Language: En Journal: Small Journal subject: ENGENHARIA BIOMEDICA Year: 2022 Document type: Article Affiliation country: United States Publication country: ALEMANHA / ALEMANIA / DE / DEUSTCHLAND / GERMANY