Your browser doesn't support javascript.
loading
Fluorescence measurements: importance of G-factor correction, magic angle, and observation wavelengths.
Kitchner, Emma; Seung, Michael; Chavez, Jose; Ceresa, Luca; Kimball, Joseph; Gryczynski, Ignacy; Gryczynski, Zygmunt.
Affiliation
  • Kitchner E; Department of Physics and Astronomy, Texas Christian University, Fort Worth, TX, 76129, United States of America.
  • Seung M; Department of Physics and Astronomy, Texas Christian University, Fort Worth, TX, 76129, United States of America.
  • Chavez J; Department of Physics and Astronomy, Texas Christian University, Fort Worth, TX, 76129, United States of America.
  • Ceresa L; Department of Physics and Astronomy, Texas Christian University, Fort Worth, TX, 76129, United States of America.
  • Kimball J; Department of Physics and Astronomy, Texas Christian University, Fort Worth, TX, 76129, United States of America.
  • Gryczynski I; Department of Physics and Astronomy, Texas Christian University, Fort Worth, TX, 76129, United States of America.
  • Gryczynski Z; Department of Physics and Astronomy, Texas Christian University, Fort Worth, TX, 76129, United States of America.
Methods Appl Fluoresc ; 10(4)2022 Sep 26.
Article in En | MEDLINE | ID: mdl-36113439
Excitation and emission (observation) conditions heavily impact fluorescence measurements. Both observed spectra and intensity decays (fluorescence lifetimes), when incorrectly measured, may lead to incorrect data interpretations. In this report, we discuss the role of observation conditions in steady-state and time-resolved (lifetime) fluorescence measurements. We demonstrate the importance of the correction for uneven transmissions of vertical and horizontal polarizations of emission light through the detection system. The necessity of using so-called total fluorescence intensity or intensity measured under magic angle (MA) conditions has been demonstrated for both steady-state and time-resolved fluorescence measurements. The dependence of lifetime measurements on observation (emission) wavelengths is also discussed. Two fluorophores, rhodamine 6G (R6G) and 4,4 Dimethylamino-cyano stilbene (DCS) in two solvents - ethanol and glycerol have been used in order to cover a broad range of dye polarities and solvent viscosities.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Methods Appl Fluoresc Year: 2022 Document type: Article Affiliation country: United States Country of publication: United kingdom

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Methods Appl Fluoresc Year: 2022 Document type: Article Affiliation country: United States Country of publication: United kingdom