Your browser doesn't support javascript.
loading
Clinical Utility of Rapid On-Site Evaluation of Touch Imprint Cytology during Cryobiopsy for Peripheral Pulmonary Lesions.
Muto, Yutaka; Uchimura, Keigo; Imabayashi, Tatsuya; Matsumoto, Yuji; Furuse, Hideaki; Tsuchida, Takaaki.
Affiliation
  • Muto Y; Department of Endoscopy, Respiratory Endoscopy Division, National Cancer Center Hospital, 5-1-1 Tsukiji Chuo-ku, Tokyo 104-0045, Japan.
  • Uchimura K; Department of Respiratory Medicine, Japanese Red Cross Medical Center, 4-1-22 Hiroo Shibuya-ku, Tokyo 150-8953, Japan.
  • Imabayashi T; Department of Endoscopy, Respiratory Endoscopy Division, National Cancer Center Hospital, 5-1-1 Tsukiji Chuo-ku, Tokyo 104-0045, Japan.
  • Matsumoto Y; Department of Endoscopy, Respiratory Endoscopy Division, National Cancer Center Hospital, 5-1-1 Tsukiji Chuo-ku, Tokyo 104-0045, Japan.
  • Furuse H; Department of Endoscopy, Respiratory Endoscopy Division, National Cancer Center Hospital, 5-1-1 Tsukiji Chuo-ku, Tokyo 104-0045, Japan.
  • Tsuchida T; Department of Endoscopy, Respiratory Endoscopy Division, National Cancer Center Hospital, 5-1-1 Tsukiji Chuo-ku, Tokyo 104-0045, Japan.
Cancers (Basel) ; 14(18)2022 Sep 16.
Article in En | MEDLINE | ID: mdl-36139653
ABSTRACT
Cryobiopsy enables us to obtain larger specimens than conventional forceps biopsy despite the caution regarding complications. This study aimed to evaluate the clinical utility of rapid on-site evaluation of touch imprint cytology (ROSE-TIC) during cryobiopsy of peripheral pulmonary lesions (PPLs). We retrospectively reviewed the data of consecutive patients who underwent cryobiopsy for solid PPLs between June 2020 and December 2021. ROSE-TIC was performed on the first specimen obtained via cryobiopsy and assessed using Diff-Quik staining. The results of ROSE-TIC for each patient were compared with the histological findings of the first cryobiopsy specimen. Sixty-three patients were enrolled in this study. Overall, 57 (90.5%) lesions were ≤30 mm in size and 37 (58.7%) had positive bronchus signs. The radial endobronchial ultrasound findings were located within and adjacent to the lesion in 46.0% and 54.0% of the cases, respectively. The sensitivity, specificity, and positive and negative predictive values of the ROSE results for histological findings of the corresponding specimens were 69.8%, 90.0%, 93.8%, and 58.1%, respectively. The concordance rate was 76.2%. In conclusion, ROSE-TIC, due to its high specificity and positive predictive value, may be a potential tool in deciding whether cryobiopsy sampling could be finished during bronchoscopy.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Prognostic_studies Language: En Journal: Cancers (Basel) Year: 2022 Document type: Article Affiliation country: Japan

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Prognostic_studies Language: En Journal: Cancers (Basel) Year: 2022 Document type: Article Affiliation country: Japan