Your browser doesn't support javascript.
loading
Comparing Pentacam HR Screening Indices in Different Normal Corneal Thicknesses among Refractive Surgery Candidates.
Ghiasian, Leila; Abdolalizadeh, Parya; Hadavandkhani, Ali; Eshaghi, Acieh; Hadi, Yasaman; Nadjafi-Semnani, Fatemeh.
Affiliation
  • Ghiasian L; Eye Research Center, The Five Senses Institute, Rassoul Akram Hospital, Iran University of Medical Sciences, Tehran, Iran.
  • Abdolalizadeh P; Eye Research Center, The Five Senses Institute, Rassoul Akram Hospital, Iran University of Medical Sciences, Tehran, Iran.
  • Hadavandkhani A; Eye Research Center, The Five Senses Institute, Rassoul Akram Hospital, Iran University of Medical Sciences, Tehran, Iran.
  • Eshaghi A; Department of Ophthalmology, Imam Hossein Medical Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Hadi Y; Eye Research Center, The Five Senses Institute, Rassoul Akram Hospital, Iran University of Medical Sciences, Tehran, Iran.
  • Nadjafi-Semnani F; Eye Research Center, The Five Senses Institute, Rassoul Akram Hospital, Iran University of Medical Sciences, Tehran, Iran.
J Curr Ophthalmol ; 34(2): 200-207, 2022.
Article in En | MEDLINE | ID: mdl-36147272
Purpose: To compare Pentacam indices in normal eyes with different corneal thicknesses. Methods: It is a retrospective observational study. Ninety-six normal eyes of 96 patients who were referred for refractive surgery in a tertiary university-based hospital from October 2015 to April 2019 were recruited consecutively. Corneal keratometry as well as Pentacam's software Belin-Ambrósio Enhanced Ectasia Display (BAD) parameters including pachymetry progression indices (PPIs), maximum Ambrosio's relational thickness (ART-max), corneal elevations, normalized deviations, BAD total deviation value (BAD-D), and anterior surface indices were measured by Pentacam HR (Type 70900). The included were classified as thin (26 eyes), average (45 eyes), and thick (25 eyes) corneas with the thinnest point thickness of ≤496 µm, 497-595 µm, and ≥596 µm, respectively. The specificities of all parameters were calculated based on routine cut-off values. Results: The refraction, keratometry, and elevations were not different (P > 0.05). All PPIs (minimum, average, and maximum) of thick corneas were significantly lower than average and thin corneas (P < 0.001). ART-max increased by thickening of the cornea (P < 0.001). BAD-D score and normalized indices of pachymetric parameters decreased with the increase of thickness (P < 0.001), while specificities of all indices increased with corneal thickening. More than 96% of thick corneas were classified as normal PPI-max (24/25), ART-max (25/25), and BAD-D (25/25), while nearly <54% of thin corneas (14/26 for PPI-max, 9/26 for ART-max, and 12/26 for BAD-D) were normal. Conclusions: The pachymetry-related indices and BAD-D were different among normal corneas with various thicknesses. The specificities of PPIs, ART-max, and BAD-D of thin corneas were lower than in thick corneas.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies / Observational_studies / Prognostic_studies / Screening_studies Language: En Journal: J Curr Ophthalmol Year: 2022 Document type: Article Affiliation country: Iran Country of publication: India

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Diagnostic_studies / Observational_studies / Prognostic_studies / Screening_studies Language: En Journal: J Curr Ophthalmol Year: 2022 Document type: Article Affiliation country: Iran Country of publication: India