Percutaneous Retrieval of a Misinserted Pigtail Catheter Straightener during Infra-Renal Abdominal Aortic Stenting: A Case Report.
Izumi, Yuichiro; Ikeda, Shuji; Kitagawa, Akira; Imaeda, Yusuke; Yamada, Tetsuya; Hagihara, Makiyo; Ota, Toyohiro; Ishiguchi, Tsuneo; Suzuki, Kojiro.
Affiliation
  • Izumi Y; Department of Radiology, Aichi Medical University, Japan.
  • Ikeda S; Department of Radiology, Aichi Medical University, Japan.
  • Kitagawa A; Department of Radiology, Aichi Medical University, Japan.
  • Imaeda Y; Department of Vascular Surgery, Aichi Medical University, Japan.
  • Yamada T; Department of Vascular Surgery, Aichi Medical University, Japan.
  • Hagihara M; Department of Radiology, Aichi Medical University, Japan.
  • Ota T; Department of Radiology, Aichi Medical University, Japan.
  • Ishiguchi T; Department of Radiology, Aichi Medical University, Japan.
  • Suzuki K; Department of Radiology, Aichi Medical University, Japan.
Interv Radiol (Higashimatsuyama) ; 5(3): 145-149, 2020 Oct 30.
Article in En | MEDLINE | ID: mdl-36284757
ABSTRACT
Percutaneous retrieval of an intravascular foreign body is a minimally invasive technique. Using cone-beam computed tomography and the lateral grasp technique, we successfully retrieved a pigtail catheter straightener that had been misinserted into the right common iliac artery. Some examples of catheter straightener retrieval have been reported; however, it is important to take care not to accidentally insert a catheter straightener into a vessel via an angiographic sheath.