Your browser doesn't support javascript.
loading
Multimodal Imaging of a Chimney-Stenting Procedure Performed Simultaneously with a Transcatheter Aortic Valve Replacement (TAVR) in a Reanimated Human Heart including Post-Implant Analyses.
Bielecki, Michael A; DeVos, Amanda N; Bianchini, Francesco; Iaizzo, Paul A.
Affiliation
  • Bielecki MA; Departments of Surgery and Biomedical Engineering, Institute for Engineering in Medicine, University of Minnesota, Minneapolis, MN 55455, USA.
  • DeVos AN; Departments of Surgery and Biomedical Engineering, Institute for Engineering in Medicine, University of Minnesota, Minneapolis, MN 55455, USA.
  • Bianchini F; Cardiology, Fondazione Policlinico Universitario Agostino Gemelli, 00168 Metropolitan City of Rome, Italy.
  • Iaizzo PA; Departments of Surgery and Biomedical Engineering, Institute for Engineering in Medicine, University of Minnesota, Minneapolis, MN 55455, USA.
J Cardiovasc Dev Dis ; 9(12)2022 Nov 24.
Article in En | MEDLINE | ID: mdl-36547410
ABSTRACT
Transcatheter aortic valve replacement (TAVR) has become a popular treatment option for severe aortic stenosis for patients with a high risk for mortality with surgical aortic valve replacement (SAVR). Coronary artery occlusion (CAO) following the implantation of the device is a potential and sometimes devastating complication of this procedure, that provokes a sudden deterioration of hemodynamic status followed by cardiogenic shock and electrical instability. With patients that present a high risk for coronary obstruction, coronary protection with a chimney stenting technique is an effective strategy that can ensure coronary perfusion during TAVR in case of acute CAO. Utilizing Visible Heart® methodologies, a human heart was reanimated. A chimney stenting technique was implemented simultaneously with the deployment of a Medtronic Evolut™ Pro+ valve (Medtronic PLC; Minneapolis, MN, USA). The entire procedure was recorded utilizing endoscopic cameras, fluoroscopy, optical coherence tomography, and echocardiography. In addition to these procedural visualizations, post-procedural micro-computed tomography (micro-CT) was conducted to provide post-implantation imaging with approximately 60-micron resolution. Utilizing these imaging modalities in a reanimated human heart allows for the unique opportunity to collect data for TAVR procedures in real human anatomies for the subsequent educational uses by the physicians treating aortic valvular disease and/or the designers of future TAVR technologies and procedures.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Cardiovasc Dev Dis Year: 2022 Document type: Article Affiliation country: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Cardiovasc Dev Dis Year: 2022 Document type: Article Affiliation country: United States