Your browser doesn't support javascript.
loading
A Tetranuclear Copper(II)/Calcium(II) Complex as Dual Chemosensor for Colorimetric and Fluorescent Detection of Non-Steroidal Anti-Inflammatory Drugs.
Macedi, Eleonora; Giorgi, Luca; Formica, Mauro; Rossi, Patrizia; Paderni, Daniele; Paoli, Paola; Fusi, Vieri.
Affiliation
  • Macedi E; Department of Pure and Applied Sciences, University of Urbino "Carlo Bo", Via della Stazione 4, 61029, Urbino, Italy.
  • Giorgi L; Department of Pure and Applied Sciences, University of Urbino "Carlo Bo", Via della Stazione 4, 61029, Urbino, Italy.
  • Formica M; Department of Pure and Applied Sciences, University of Urbino "Carlo Bo", Via della Stazione 4, 61029, Urbino, Italy.
  • Rossi P; Department of Industrial Engineering, University of Florence, via S. Marta 3, 50139, Florence, Italy.
  • Paderni D; Department of Pure and Applied Sciences, University of Urbino "Carlo Bo", Via della Stazione 4, 61029, Urbino, Italy.
  • Paoli P; Department of Industrial Engineering, University of Florence, via S. Marta 3, 50139, Florence, Italy.
  • Fusi V; Department of Pure and Applied Sciences, University of Urbino "Carlo Bo", Via della Stazione 4, 61029, Urbino, Italy.
Chempluschem ; 88(5): e202200364, 2023 05.
Article in En | MEDLINE | ID: mdl-36658696
The tetranuclear Cu2+ /Ca2+ /Ca2+ /Cu2+ complex based on Malten ligand has been investigated as a platform for anion binding. Simple organic carboxylates and non-steroidal anti-inflammatory drugs (NSAIDs) have been tested, revealing the ability of the platform to bind them. The receiving platform hosts at least two guests in solution although a third anion can be bound, as suggested by X-ray diffraction analysis. The addition of the anions is accompanied by a color change of the solution, making the system a colorimetric sensor for carboxylates (LOD values comprised between 3.6 and 20.7 ppm). A fluorescent system consisting of the 2-(3-oxido-6-oxoxanthen-9-yl)benzoate (fluorescein anion) linked to the tetranuclear platform has been also prepared and used in a chemosensing ensemble approach to signal the presence of the selected anions (Log K between 2.6 and 5.6 for the addition of two guests). The latter also works in a paper strip test, offering the chemosensor a possible practical application.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Calcium / Copper Type of study: Diagnostic_studies Language: En Journal: Chempluschem Year: 2023 Document type: Article Affiliation country: Italy Country of publication: Germany

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Calcium / Copper Type of study: Diagnostic_studies Language: En Journal: Chempluschem Year: 2023 Document type: Article Affiliation country: Italy Country of publication: Germany