Your browser doesn't support javascript.
loading
One-Piece Zirconia Oral Implants for the Support of Three-Unit Fixed Dental Prostheses: Three-Year Results from a Prospective Case Series.
Kohal, Ralf-Joachim; Vach, Kirstin; Butz, Frank; Spies, Benedikt Christopher; Patzelt, Sebastian Berthold Maximilian; Burkhardt, Felix.
Affiliation
  • Kohal RJ; Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center-University of Freiburg, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany.
  • Vach K; Institute of Medical Biometry and Statistics, Faculty of Medicine, Medical Center-University of Freiburg, University of Freiburg, Zinkmattenstr. 6a, 79108 Freiburg, Germany.
  • Butz F; Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center-University of Freiburg, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany.
  • Spies BC; Private Dental Clinic, Belchenstr. 6a, 79189 Bad Krozingen, Germany.
  • Patzelt SBM; Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center-University of Freiburg, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany.
  • Burkhardt F; Department of Prosthetic Dentistry, Faculty of Medicine, Center for Dental Medicine, Medical Center-University of Freiburg, University of Freiburg, Hugstetter Str. 55, 79106 Freiburg, Germany.
J Funct Biomater ; 14(1)2023 Jan 13.
Article in En | MEDLINE | ID: mdl-36662092
ABSTRACT
The objective was to investigate the clinical and radiological outcome of one-piece zirconia oral implants to support three-unit fixed dental prostheses (FDP) after three years in function. Twenty-seven patients were treated with a total of 54 implants in a one-stage surgery and immediate provisionalization. Standardized radiographs were taken at implant placement, after one year and after three years, to evaluate peri-implant bone loss. Soft-tissue parameters were also assessed. Linear mixed regression models as well as Wilcoxon Signed Rank tests were used for analyzing differences between groups and time points (p < 0.05). At the three-year evaluation, one implant was lost, resulting in a cumulative survival rate of 98.1%. The mean marginal bone loss amounted to 2.16 mm. An implant success grade I of 52% (bone loss of ≤2 mm) and success grade II of 61% (bone loss of ≤3 mm) were achieved. None of the evaluated baseline parameters affected bone loss. The survival rate of the zirconia implants was comparable to market-available titanium implants. However, an increased marginal bone loss was observed with a high peri-implantitis incidence and a resulting low implant success rate.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Risk_factors_studies Language: En Journal: J Funct Biomater Year: 2023 Document type: Article Affiliation country: Germany

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Risk_factors_studies Language: En Journal: J Funct Biomater Year: 2023 Document type: Article Affiliation country: Germany