Your browser doesn't support javascript.
loading
Thoracic motion-compensated cone-beam computed tomography in under 20 seconds on a fast-rotating linac: A simulation study.
Blake, Samuel J; Dillon, Owen; Byrne, Hilary L; O'Brien, Ricky T.
Affiliation
  • Blake SJ; ACRF Image X Institute, Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia.
  • Dillon O; ACRF Image X Institute, Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia.
  • Byrne HL; ACRF Image X Institute, Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia.
  • O'Brien RT; ACRF Image X Institute, Sydney School of Health Sciences, Faculty of Medicine and Health, The University of Sydney, Sydney, New South Wales, Australia.
J Appl Clin Med Phys ; 24(3): e13909, 2023 Mar.
Article in En | MEDLINE | ID: mdl-36680744
BACKGROUND: Rapid kV cone-beam computed tomography (CBCT) scans are achievable in under 20 s on select linear accelerator systems to generate volumetric images in three dimensions (3D). Daily pre-treatment four-dimensional CBCT (4DCBCT) is recommended in image-guided lung radiotherapy to mitigate the detrimental effects of respiratory motion on treatment quality. PURPOSE: To demonstrate the potential for thoracic 4DCBCT reconstruction using projection data that was simulated using a clinical rapid 3DCBCT acquisition protocol. METHODS: We simulated conventional (1320 projections over 4 min) and rapid (491 projections over 16.6 s) CBCT acquisitions using 4D computed tomography (CT) volumes of 14 lung cancer patients. Conventional acquisition data were reconstructed using the 4D Feldkamp-Davis-Kress (FDK) algorithm. Rapid acquisition data were reconstructed using 3DFDK, 4DFDK, and Motion-Compensated FDK (MCFDK). Image quality was evaluated using Contrast-to-Noise Ratio (CNR), Tissue Interface Width (TIW), Root-Mean-Square Error (RMSE), and Structural SIMilarity (SSIM). RESULTS: The conventional acquisition 4DFDK reconstructions had median phase averaged CNR, TIW, RMSE, and SSIM of 2.96, 8.02 mm, 83.5, and 0.54, respectively. The rapid acquisition 3DFDK reconstructions had median CNR, TIW, RMSE, and SSIM of 2.99, 13.6 mm, 112, and 0.44 respectively. The rapid acquisition MCFDK reconstructions had median phase averaged CNR, TIW, RMSE, and SSIM of 2.98, 10.2 mm, 103, and 0.46, respectively. Rapid acquisition 4DFDK reconstruction quality was insufficient for any practical use due to sparse angular projection sampling. CONCLUSIONS: Results suggest that 4D motion-compensated reconstruction of rapid acquisition thoracic CBCT data are feasible with image quality approaching conventional acquisition CBCT data reconstructed using standard 4DFDK.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Image Processing, Computer-Assisted / Cone-Beam Computed Tomography Type of study: Guideline Limits: Humans Language: En Journal: J Appl Clin Med Phys Journal subject: BIOFISICA Year: 2023 Document type: Article Affiliation country: Australia Country of publication: United States

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Image Processing, Computer-Assisted / Cone-Beam Computed Tomography Type of study: Guideline Limits: Humans Language: En Journal: J Appl Clin Med Phys Journal subject: BIOFISICA Year: 2023 Document type: Article Affiliation country: Australia Country of publication: United States